SYNTHESIZER/SEQUENCER PART

(1) TRANSMIT FLOW

MIDI <-+-[SW1]--+---------NOTE ON/OFF 9nH
OUT | |
| +---------KEY'S AFTER TOUCH AnH (Seq only)
| |
| +---------CONTROL CHANGE (All in Seq)
| | MODULATION BnH,01H
| | VOLUME BnH,07H
| | PAN BnH,0AH
| | SUSTAIN SWITCH BnH,40H
| | FILTER RESONANCE BnH,47H
| | EG RELEASE TIME BnH,48H
| | EG ATTACK TIME BnH,49H
| | FILTER CUTOFF FREQ BnH,4AH
| | EG DECAY TIME BnH,4BH
| | REVERB SEND BnH,5BH
| | CHORUS SEND BnH,5DH
| | ASSIGNABLE CONTROLLERS BnH,(00H..5FH)
| | SEQ REMOTE CONTROL BnH,(00H..7FH)
| |
| +--[SW7]--BANK SEL MSB BnH,00H
| | BANK SEL LSB BnH,20H
| |
| +---------CHANNEL MODE MESSAGE (Seq only)
| | RESET ALL CONTROLLERS BnH,79H
| | LOCAL CONTROL BnH,7AH
| | OMNI MODE OFF BnH,7CH
| | OMNI MODE ON BnH,7DH
| | MONO MODE ON BnH,7EH
| | POLY MODE ON BnH,7FH
| |
| +--[SW8]--PROGRAM CHANGE CnH
| |
| +---------CHANNEL AFTER TOUCH DnH
| |
| +---------PITCH BEND CHANGE EnH
|
+--[SW4]------------SYSTEM COMMON MESSAGE
| SONG POSITION POINTER F2H
| SONG SELECT F3H
|
+--[SW4]-----------SYSTEM REALTIME MESSAGE
| TIMING CLOCK F8H
| START FAH
| CONTINUE FBH
| STOP FCH
|
+-------------------ACTIVE SENSING FEH
|
+--[SW5]-+----------SYSTEM EXCLUSIVE MESSAGE (All in Seq)
| +--[SW6]-- <BULK DUMP>
| | F0H 43H 0nH 7FH 00H bhH blH ahH amH alH ddH....ddH ccH F7H *3
| |
| +--[SW6]-- <PARAMETER CHANGE>
| F0H 43H 1nH 7FH 00H ahH amH alH ddH.....ddH F7H *3
|
+-------------------SYSTEM EXCLUSIVE MESSAGE
| IDENTITY REPLY
| F0H 7EH 7FH 06H 02H 43H 00H 41H 69H (or 6AH or 6BH) 05H 00H 00H
| 00H 7FH F7H
+--[SW3,4]----------MIDI MACHINE CONTROL
STOP F0H 7FH 7FH 06H 01H F7H
DEFERRED PLAY F0H 7FH 7FH 06H 03H F7H
LOCATE F0H 7FH 7FH 06H 44H 06H 01H hrH
mnH scH frH ffH F7H
[SW1] MIDI Transmit Channel
In the Master mode: complies with Zone Transmit Channel.
In the mode other than the Master: complies with Keyboard Transmit Channel.
The sequence data played back in the Song/Pattern mode is transmitted according to the MIDI Filter settings.
[SW2] MIDI Control Mode
[SW3] MIDI Sync (transmitted when the MIDI Sync is set to MTC.)
[SW4] Seq MIDI Control
[SW5] MIDI Device Number
When set to all, transmitted via 1.
The sequence data played back in the Song/Pattern mode is transmitted according to the MIDI Filter settings.
[SW6] The System data can be transmitted/recognized in any mode.
Regarding the other types of data, it depends on the current mode whether they can be transmitted/recognized or
not.
[SW7] SYSTEM Bank Select Switch
[SW8] SYSTEM Program Change Switch

(2) RECEIVE FLOW

MIDI>-+-[SW10]--+---------NOTE OFF 8nH
| |
| +---------NOTE ON/OFF 9nH
| |
| +---------KEY'S AFTER TOUCH AnH (Seq only)
| |
| +---------CONTROL CHANGE (All in Seq)
| | MODULATION BnH,01H
| | PORTAMENTO TIME BnH,05H
| | DATA ENTRY MSB BnH,06H
| | DATA ENTRY LSB BnH,26H
| | MAIN VOLUME BnH,07H
| | PAN BnH,0AH
| | EXPRESSION BnH,0BH
| | SUSTAIN SWITCH BnH,40H
| | PORTAMENTO SWITCH BnH,41H
| | SOSTENUTO BnH,42H
| | HARMONIC CONTENT BnH,47H
| | EG RELEASE TIME BnH,48H
| | EG ATTACK TIME BnH,49H
| | BRIGHTNESS BnH,4AH
| | EG DECAY TIME BnH,4BH
| | EFFECT1 DEPTH BnH,5BH
| | EFFECT3 DEPTH BnH,5DH
| | DATA ENTRY INC BnH,60H
| | DATA ENTRY DEC BnH,61H
| | ALL SOUND OFF BnH,78H
| | ASSIGNABLE CONTROLLER BnH,(00H..5FH)
| | NRPN BnH,62H,63H *2
| | RPN
| | PITCH BEND SENS. BnH,64H,00H,65H,00H,06H,mmH
| | FINE TUNING BnH,64H,01H,65H,00H,06H,mmH,
| | 26H,llH
| | COARSE TUNING BnH,64H,02H,65H,00H,06H,mmH
| | RPN RESET BnH,64H,7FH,65H,7FH
| +--[SW2]--EG SUSTAIN LEVEL BnH,1FH
| |
| +--[SW7]--BANK SEL MSB BnH,00H
| | BANK SEL LSB BnH,20H
| |
| +---------CHANNEL MODE MESSAGE
| | RESET ALL CONTROLLERS BnH,79H
| | LOCAL CONTROL BnH,7AH
| | OMNI MODE OFF BnH,7CH
| | OMNI MODE ON BnH,7DH
| | MONO MODE ON BnH,7EH
| | POLY MODE ON BnH,7FH
| |
| +--[SW8]--PROGRAM CHANGE CnH
| |
| +---------CHANNEL AFTER TOUCH DnH
| |
| +---------PITCH BEND CHANGE EnH
|
+--[SW3]------------SYSTEM COMMON MESSAGE
| MTC QUARTER FRAME MESSAGE F1H
|
+--[SW4]------------SYSTEM COMMON MESSAGE
| SONG POSITION POINTER F2H
| SONG SELECT F3H
|
+--[SW3]------------SYSTEM REALTIME MESSAGE
| TIMING CLOCK F8H
|
+--[SW4]------------SYSTEM REALTIME MESSAGE
| START FAH
| CONTINUE FBH
| STOP FCH
|
+-------------------ACTIVE SENSING FEH
|
+--[SW5]-+-----+----SYSTEM EXCLUSIVE MESSAGE (All in Seq)
| | MIDI MASTER VOLUME F0H 7FH 7FH 04H 01H llH mmH F7H
| |
| +--[SW9]---<BULK DUMP>
| | F0H 43H 0nH 7FH 00H bhH blH ahH amH alH ddH....ddH ccH F7H *3
| |
| +--[SW6]---<PARAMETER CHANGE>
| | F0H 43H 1nH 7FH 00H ahH amH alH ddH.....ddH F7H *3
| |
| +--[SW6]---<BULK DUMP REQUEST>
| | F0H 43H 2nH 7FH 00H ahH amH alH ddH.....ddH F7H *3
| |
| +--[SW6]---<PARAMETER REQUEST>
| | F0H 43H 3nH 7FH 00H ahH amH alH F7H *3
| |
| +--[SW11]--XG SYSTEM ON
| | F0H 43H 1nH 4CH 00H 00H 7EH 00H F7H
| |
| +--[SW11]--GM MODE ON
| F0H 7EH 7FH 09H 01H F7H
|
+-------------------SYSTEM EXCLUSIVE MESSAGE
IDENTITY REQUEST F0H 7EH 0nH 06H 01H F7H
SECTION CONTROL F0H 43H 7EH 00H ssH 7FH F7H
(Pattern Mode only)
[SW2] MIDI Control Mode
[SW3] MIDI Sync (can be set to “internal,” “MIDI,” or “MTC.”)
[SW4] Seq MIDI Control
[SW5] MIDI Device Number
When this is not set to off, the MIDI Master Volume can be recognized in any mode.
The sequence data played back in the Song/Pattern mode is transmitted according to the MIDI Filter settings.
[SW6] The System data can be transmitted/recognized in any mode.
Regarding the other types of data, it depends on the current mode whether they can be transmitted/recognized or
not.
[SW7] SYSTEM Bank Select Switch
[SW8] SYSTEM Program Change Switch
[SW9] SYSTEM Bulk Protect and same as SW6.
[SW10] MIDI Receive Channel and Receive Filter
In the Song/Pattern mode: complies with Part Receive Channel and Part Receive Switch.
In the other mode: complies with Basic Receive Channel.
The sequence data recorded to the Song/Pattern is recognized according to the MIDI Filter settings.
[SW11] SYSTEM Receive GM/XG On
*2: Available only for the Plug-in voices
*3: Recognized/transmitted only when the Plug-in voice (MODEL ID = 0x64) is selected.
64 Data List
MIDI Data Format