DME-N Network Driver Installation Guide for LS9 6
[Remove ALL] Button
Deletes all devices from the list.
[Undo] Button
This button provides a one-step undo function that allows you to undo a single operation and revert to
the previous state. The [Undo] button will be grayed out and inaccessible immediately after an undo
operation or after the control panel is launched.
2 Device Information
When a device that is registered for communication with the DME-N Network Driver is selected in the Target
Device List, the communication parameters for that device can be viewed and edited in the Device
Information fields.
Device Name
This is the name of the device selected in the Target Device List. The initial default settings are “UNIT1”
through “UNIT256,” but the name can be edited as required in the Device Name field.
Device IP Address
The IP address of the device selected in the Target Device List can be set via these fields. To
communicate with the LS9, enter the IP address set in the MISC SETUP screen of the LS9 console.
nThe IP address must be set properly or communication with the device will not be possible.
Device MAC Address
The MAC (Media Access Control) address of the device selected in the Target Device List can be set via
these fields. The MAC address of each device is permanently assigned when the device is
manufactured and cannot be changed. The MAC address parameter is included to prevent data from
being sent to the wrong device if the IP address in inadvertently set incorrectly. To communicate with the
LS9, you can confirm the MAC address in the MISC SETUP screen of the LS9 console.
nThe MAC address must be set properly or communication with the device will not be possible.
nThe MAC address of the connected device cannot be changed.
Device Port No.
The MIDI port number of the device selected in the Target Device List can be set via this menu. The MIDI
port number also functions as device ID number. It should be set to “1” for LS9.
nThe MIDI port number must be set properly or communication with the device will not be possible.
[Apply] Button
Click the [Apply] button after editing the Device Name, Device IP Address, Device MAC Address, or
Device Port No. parameters to actually apply the changes. Also, devices added to the Target Device List
(1) by pressing the [NEW] or [DUPLICATE] buttons will only actually be registered for communication
with the DME-N Network Driver when the [Apply] button is pressed.
3 [Advanced Settings] Button
Opens the “Advanced Settings” window.
This window provides access to advanced settings. For details refer to the “Advanced Settings” Window
section.
4When all parameters have been set up as required, click the [Save and Close] button to close the
“DME-N Network Driver” window and save the settings.
This button is not accessible while an application that is using the DME-N Network Driver is running.
nClick the [Cancel] button if you want to close the window without saving any changes.