9
—Owner’s Manual
Recorder Section
L
PITCH control
This rotary control adjusts the tape speed in the range of
±
10%.
M
Tape speed switch
This switch is used to select 4.8 cm/second or 9.5 cm/second for the tape speed. Set the switch
to 9.5 ( ) for normal recording, and 4.8 ( ) for playback of a tape recorded with a normal
cassette tape recorder.
N
REC SELECT switches
These switches are used to select recording sources for tracks.
– ...Input channel (1–4) signals are routed directly to the corresponding tracks for
recording (direct recording).
OFF
.............The corresponding tracks are disabled for recording.
L/R
..............The corresponding tracks are ready for recording and receive L channel (Tracks 1
and 3) or R channel (Tracks 2 and 4) signals.
O
METER SELECT switch
This switch selects the signal level to be displayed on the level meters
a
.
............The level meters display the track input signal levels during recording and the
track output signal levels during playback.
STEREO
....The level meters display the Stereo bus signal levels (signal output from the
STEREO OUT jacks).
Pdbx switch
Use this switch to turn on and off the dbx noise reduction system.
ON...............The dbx noise reduction system is turned on for all tracks.
OFF.............The dbx noise reduction system is turned off for all tracks.
SYNC.........The dbx noise reduction system is turned off only for Track 4.
Note: The SYNC setting is used for a special application in which Track 4 is used for
synchronization. See page 41 for more information.
4TR4STEREO
METER SELECTREC SELECT
ZERO STOP
PITCH
NOISE REDUCTION SYSTEM
TAPE SPEED CONTROL
OFF
R
3
OFF
L
2
OFF
R
1
OFF
L
ON
OFF
ON
OFF
SYNC
4.8/ 9.5
–+
ONLM
QP
R
S
T
1 4
4TR