44
—Owner’s Manual
Appendix

Troubleshooting

If you are having difficulty operating the MT400 or it does not seem to work as expected, look

up the symptoms in the following table and note the offered advice.

Symptom Advice
MT400 cannot be turned on.
Make sure the AC adapter is connected to a suitable AC wall outlet
securely and plugged into the DC 12V connector at the rear of the
MT400.
Make sure that a correct AC adapter is being used.
Make sure that the MT400 POWER switch is set to the ON position.
Cannot listen to a connected music
source.
Make sure that the [INPUT-FLIP] switches and the monitor select
switch are set to the appropriate positions. When an [INPUT-FLIP]
switch is set to MIC/LINE ( ), raise the corresponding input
channel fader and the STEREO fader, and set the monitor select
switch to STEREO or ST+CUE. When an [INPUT-FLIP] switch is
set to TAPE ( ), raise the corresponding channel CUE control
and the STEREO fader, and set the monitor select switch to STE-
REO or ST+CUE.
Cannot push in the button. Make sure that tapes write-protect tabs are intact.
Cannot record.
Make sure that the [REC SELECT] switch is not set to OFF.
Make sure that you have assigned the signal that you want to record
to the track. Use the CUE control to see if the signal is actually being
sent to the track.
The level meters do not indicate sig-
nal levels.
Make sure that the [METER SELECT] switch is set correctly.
Make sure that the recording track is in recording pause mode.
Recordings are noisy.
Use the dbx noise reduction.
Make sure that the recording level is set correctly. Too low a signal
level will cause the tape hiss to be more noticeable.
Recordings are distorted. Make sure that the recording level is set correctly. Too high a signal
level will cause distortion.
Recordings sound dull.
Abnormal tape hiss.
Wow and flutter.
Fluctuating output level.
Clean the record-play head and other parts of the tape transport.
Demagnetize the record-play head.
Recordings play back at a lower (or
higher) pitch by one octave. Use the same tape speed as for recording.
Cannot send a channel signal to the
AUX SEND.
In addition to turning up the AUX control, you must also raise the
channel fader. This is because the AUX SEND signal is source post-
fader (i.e., after the fader).
MIDI sequencer does not synchronize
to the MT400.
Make sure that the FSK/MIDI or SMPTE/MIDI converter is set to con-
vert the recorded SYNC signal into MIDI Clock or MTC.
Make sure that your MIDI sequencer is set to synchronize to an
external MIDI Clock or MTC. Refer to the MIDI sequencers user
manual.
REC