R Remote Operation Manual 12
Here you can view and edit detailed HA settings for the R series unit. This appears when you click a
connector index in the main screen. The toolbar also shows the UNIT ID of the R series unit. To close
the dialog box, click the [x] button located in the upper right.
① Connector index
Indicates the connector number of the R series unit. If you click this, the indicator of the
corresponding connector of the R series unit will light.
② [+48V] button
Turns the phantom power on/off.
③ [A.GAIN] knob
Specifies the analog gain for the HA of the R series unit. The current setting is shown in the
numeric box located below the knob. The level meter located at the immediate right of the knob
indicates the input level of the corresponding port.
④ [GC] button
Switches on/off the gain compensation that regularizes the signal level on the audio network. If
this is on, the gain value fixed by gain compensation is displayed, and subsequent changes to
analog gain is compensated by the compensation gain within the R series unit; audio is
transmitted to the Dante network at the gain value that was fixed immediately before this was
enabled.
⑤ [FREQ] knob/[HPF] button
Switches on/off the high-pass filter that is built into the HA of the R series unit, and adjusts the
cutoff frequency. The current setting is shown in the numeric box located below the knob.