R Remote Operation Manual 5
When using R Remote to operate an R series unit, set the DIP switches and [UNIT ID] rotary switch of
the unit, taking note of the following settings.
・ Set the UNIT ID in the range of 1 to 8. R Remote will not detect units with a setting of 0 or 9 or
higher.
・ Set the DIP switches to one of the following states, depending on the connection type and the
START UP MODE.
Connection
START UP MODE
Dip switch
DAISY CHAIN
REFRESH
(↑↑↑↑↑↑↑↑)
RESUME
(↑↑↑↑↑↑↓↑)
REDUNDANT
REFRESH
(↑↑↑↓↑↑↑↑)
RESUME
(↑↑↑↓↑↑↓↑)
If a CL series unit is not connected, we recommend that you set START UP MODE to RESUME. If this is set to
REFRESH, settings must be transmitted from R Remote and Dante Controller each time the R series unit is
restarted. Also, if the REFRESH setting is used and R Remote is connected earlier than the CL series unit, the
orange [SYNC] indicator will be lit.