CONTROLS AND THEIR FUNCTIONS
1 | 2 |
| 3 |
|
| ||||
|
|
|
|
|
|
|
| ||
|
| INPUT2 |
|
|
| INPUT1 | |||
| AUTO |
| FROM AMPLIFIER | ||||||
| POWER |
|
|
|
|
|
|
| |
| OFF ON |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
POWER | HIGH CUT | VOLUME |
| ||
OFF |
|
|
|
|
|
ON |
|
|
|
|
|
| 50 Hz | I50 Hz | 0 | I0 |
|
|
|
|
|
| OUTPUT |
|
|
|
|
| TO SPEAKERS |
4 |
| 5 | 6 | 7 | 8 |
English
1POWER indicator
Lights in green when the POWER switch is turned ON, and goes off when turned OFF.
*STANDBY mode:
If the AUTO POWER ON/OFF switch on the rear panel is set to ON, this indicator lights in red when no signal is input to this unit.
2AUTO POWER ON/OFF switch
By setting this switch to the ON position, this unit’s automatic power ON/OFF function operates as described below. If you do not need this function, set to the OFF position.
*Make sure to change the setting of this switch only when the power of this unit is off.
Automatic power ON/OFF function
When you play a source, the power to this unit turns on automatically by sensing audio signals input to this unit. The power turns off automatically if the source being played is stopped or the input signal is cut off for several minutes.
*This function will operate responding to a certain level of input signal. Increase the output level on the input source if the automatic power ON function will not operate, or decrease the level if the automatic power OFF function will not operate.
*There may be a case that the power turns on unexpectedly by sensing noise from other appliances. If it occurs, set the AUTO POWER ON/OFF switch to the OFF position.
This function is available only when the power of this unit is on (by setting the POWER switch (4) to “on”).
3INPUT1 (FROM AMPLIFIER) terminals
Used to connect this unit with the speaker terminals of the amplifier.
4POWER switch
Turns the power of this unit ON and OFF whenever pressed. When this switch is turned ON, the POWER indicator above the POWER switch lights up.
5HIGH CUT control
Adjusts the high frequency cut off point.
Frequencies higher than the frequency selected by this control are all cut off (and not output).
*One graduation of this control represents 10 Hz.
90 | I00 |
II0 | |
80 | I20 |
70 | I30 |
60 | I40 |
50 Hz | I50 Hz |
6VOLUME control
Adjusts the volume level.
7INPUT2 terminals
Used to input line level signals from the amplifier.
8OUTPUT (TO SPEAKERS) terminals
Can be used for connections with the main speakers. These terminals send signals output from the amplifier to the main speakers directly.
9