Manuals / Brands / Musical Instruments & Equipment / Music Mixer / Yamaha / Musical Instruments & Equipment / Music Mixer

Yamaha WK83840 manual

1 80
Download 80 pages, 3.06 Mb
Contents
Main Explanation of Graphical Symbols IMPORTANT SAFETY INSTRUCTIONS CAUTION 1. IMPORTANT NOTICE: DO NOT MODIFY THIS UNIT! 2. IMPORTANT: 3. NOTE: FCC INFORMATION (U.S.A.) IMPORTANT NOTICE FOR THE UNITED KINGDOM Connecting the Plug and Cord ADVARSEL! VARNING PRECAUTIONS PLEASE READ CAREFULLY BEFORE PROCEEDING Do not open * Please keep this manual in a safe place for future reference. WARNING Connections Maintenance Handling caution Backup battery Foreword Foreword 8 Introduction to the DME64N/24N 9 Index 75 The Controls and Connectors 14 Contents Accessories (Please make sure the following items are included in the package.) Options About the Product Names About the Firmware Version Foreword Introduction to the DME64N/24N Differences between DME64N/24N DME64N/24N Features Audio System Network Glossary for the DME64N/24N Scene Scene 1 Scene Recall Scene 2 Scene change Scene Configuration Preset Parameter Signal Types DME64N/24N audio system signals can be broadly categorized as follows. 1 Audio 2 Control signals within a device group 3 Control signals between devices outside the device group System Examples ICP1 Space D SCENE NUMBER Large systems using CobraNet About DME Designer Front Panel 1[USB] Connector 2[EXT. CLOCK] Indicator 3[96kHz] [88.2kHz] [48kHz] [44.1kHz] Indicator The Controls and Connectors Page Rear Panel 1[AC IN] Connector 2Ground Screw 3[GPI] Connector 4[MIDI IN] [MIDI OUT] [MIDI THRU] Connectors 5[WORD CLOCK IN] [WORD CLOCK OUT] Connectors 8 6[NETWORK] Connector 7[REMOTE] Connector Setup 3. 4. 5. 6. 7. I/O Card Installation Compatible I/O Cards Page USB Connection USB Connection Connecting to a Computer Ethernet Connection ([NETWORK] Connector) Ethernet Connection ([NETWORK] Connector) DME64N/DME24N Owners Manual Control from a computer in the same subnet group Control from a computer with a different subnet Ethernet Connection ([NETWORK] Connector) DME64N/DME24N Owners Manual 25 Connecting multiple device groups Device Group 1 Device Group 2 Analog Audio Connection ([IN] and [OUT] Connectors) (DME24N only) Euroblock Connection 1. Audio I/O Connection 3. 4. I/O Slots Remote Connection ([REMOTE] Connector) Controlling external head ampliers from the DME64N/24N Connecting to an External Device Connecting to an External Device Remote Connection ([REMOTE] Connector) DME64N/24N Digital Mixer Controlling a DME24Ns internal head amps from a digital mixer Controlling the DME64N/24N from an external device IN OUT REMOTE REMOTE Ethernet Cable Switching D-SUB 9-pin Cable MIDI Connection ([MIDI] Connectors) Cascade Connection ([Cascade] Connectors) (DME64N only) Cascade Connection Example Connecting to an External Device WORD CLOCK Connection ([WORD CLOCK] Connectors) This method is not recommended for large systems. WORD CLOCK Connection ([WORD CLOCK] Connectors) Daisy Chain Connection Distribution Box Connection GPI Connection ([GPI] Connectors) Basic Operation Panel Operation and Displays Main Display Parameter Edit Displays Numeric Parameters 1. 2. 1. 2. 3. 1. 2. 1. 2. 3. ON/OFF Parameters 1. 2. Editing User Dened Button 1. 2. 3. 4. 5. 1. 2. Output Level Control Adjust the output level of the DME64N/24N. 1. 2. required. Scene Recall This procedure recalls a new scene (refer to page 10). 1. 2. 3. 4. Scene Store 1. 2. Monitoring 1. 2. 3. Probe Monitor Functions Spectrum Display Procedure 1. Level Meter Display 1. 2. Initializing the DME64N/ DME24N Panel Operation and Displays Utility Displays Utility Displays Most basic DME64N/24N functions can be accessed via the Utility Display. Items accessible via the Utility display Page Item Description Manual Page Info Net Page Utility Display Operation 1. 2. 3. 4. Info Page Network Settings (Net) Page Display Setup (Disp) Page Security Setup (Lock) Page Miscellaneous Setup (Misc) Page Word Clock Setup (WCLK) Page Master Clock Selection Procedure 1. 2. Slot Information (Slot) Page MIDI Setup (MIDI) Page DAW Control GPI Setup (GPI) Page Head Amplier Setup (HA) Page Cascade Setup (CASCAD) Page Check Page Options ICP1 CP4SW, CP4SF, and CP1SF References Error Messages Error messages Status messages Page Page Troubleshooting DME64N/DME24N Owners Manual 61 Troubleshooting Specifications Specications Input/Output Characteristics DME64N/DME24N Owners Manual 63 Input/Output Characteristics Terminals Gain Total Harmonic Distortion fs = 48kHz DME24N ANALOG INPUT CHARACTERISTICS DME64N ANALOG OUTPUT CHARACTERISTICS Control I/O Terminals Format Level Connector Connector Pin Assign DME64N/DME24N Owners Manual 65 Connector Pin Assign [CASCADE IN/OUT] Connectors (DME64N only) Connector Pin Assign [NETWORK] Connector (100Base-TX Ethernet, RJ-45) Straight Cables Cross Cables Straight/Cross Cable Wiring Details Pin Connection Pins Pins Dimensions Unit: mm DME24N DME64N MIDI Data Format 1. DME64N/24N MIDI Functions 1.1 Scene Change 1.2 Parameter Control 2. MIDI Data Flow Page 4.1 Program Change (Cnh) 4.2 Active Sensing (FEh) 4.3 Control Change (Bnh) 4.4 Parameter Change (F0h ~ F7h) Supplemental Information 1 + - Page Glossary DME64N/DME24N Owners Manual 73 Glossary Glossary Index A B C D I L M N O T U V W Z Page CANADA U.S.A. MEXICO BRAZIL NORTH AMERICA CENTRAL & SOUTH AMERICA EUROPE AFRICA MIDDLE EAST ASIA OCEANIA