AE00780

DC PROTECTOR

The DC protector turns off automatically when the load exceeds the generator rated output.

cC

Reduce the load to the specified generator rated output if the DC protector turns off. If it turns off again, consult a Yamaha dealer.

NOTE:

Press to reset the DC protector.

1“OFF”

2 “ON”

AE00848

G.F.C.I. RECEPTACLE (for YG2800i)

The G.F.C.I. (Ground Fault Circuit Interrupter) 1 shuts off power to the protected receptacles if a ground fault (electrical leak) is detected.

If the reset button 2 pops out 3, the equipment plugged into the receptacle may be faulty. If this hap- pens, check the equipment carefully. If the equipment appears to be in good condition, press the reset button firmly until a click is heard. This will restore power. If the reset button pops out again, unplug the equipment immediately. Have the equipment inspected and repaired by a qualified repairperson before attempting to use it again.

w

TO REDUCE THE CHANCE OF ELECTRICAL SHOCK:

9Do not attempt to operate equipment if the ground fault circuit interrupter reset button pops out repeatedly during use.

9Test the ground fault circuit interrupter during the pre-operation checks according to the maintenance instructions on page 30.

9Remember that only receptacles labeled “GFCI” have ground fault circuit interrupter protection.