q
a
w
er
AE00601
STORAGE
Long term storage of your machine will require some preventive procedures to guard against deterioration.
AE00611
DRAIN THE FUEL
1.Drain the fuel tank, fuel cock, and carburetor float bowl.
aCarburetor drain plug
2.Pour a cup of SAE 10W30 or 20W40 motor oil into the tank.
3.Shake the tank to coat the inner surfaces thor- oughly.
4.Drain off the excess oil.
AE00621
ENGINE
1. Remove the spark plug, pour about one tablespoon of SAE 10W30 or 20W40 motor oil into the spark plug hole and reinstall the spark plug. Recoil start the engine by turning over several times (with ignition off) to coat the cylinder walls with oil.
2. Pull the recoil starter until you feel compression. Then stop pulling. (This prevents the cylinder and valves from rusting).
3. Clean exterior of the generator and apply a rust inhibitor.
4. Store the generator in a dry,
5. The generator must remain in a vertical position when stored, carried or operated.
– 33 –