YDP-123 Appendix/Anhang/Annexe/Apéndice 354. PROGRAM CHANGE

Data format: [CnH] -> [ppH]

CnH = Program event (n = channel number)
ppH = Program change number
P.C.#=Program Change number
When program change reception is turned OFF, no program
change data is transmitted or received. Also, Bank MSB/LSB
is not transmitted or received.
5. SYSTEM REALTIME MESSAGES
[rrH]
F8H: Timing clock
FAH: Start
FCH: Stop
FEH: Active sensing
Caution: If an error occurs during MIDI reception, the Damper,
Sostenuto, and Soft effects for all channels are turned off and
an All Note Off occurs.
6. SYSTEM EXCLUSIVE MESSAGES(Universal System Exclusive)
(1)Universal Realtime Message

Data format: [F0H] -> [7FH] -> [XnH] -> [04H] -> [01H] ->

[llH] -> [mmH] -> [F7H]

MIDI Master Volume

Simultaneously changes the volume of all channels.
When a MIDI master volume message is received, the volume
only has affect on the MIDI receive channel, not the panel
master volume.
F0H = Exclusive status
7FH = Universal Realtime
7FH = ID of target device
04H = Sub-ID #1=Device Control Message
01H = Sub-ID #2=Master Volume
llH = Volume LSB
mmH =
Volume MSB
F7H = End of Exclusive
or
F0H = Exclusive status
7FH = Universal Realtime
XnH = When n is received n=0~F, whichever is received.
X = don’t care
04H = Sub-ID #1=Device Control Message
01H = Sub-ID #2=Master Volume
llH = Volume LSB
mmH =
Volume MSB
F7H = End of Exclusive
(2)Universal Non-Realtime Message (GM On)

General MIDI Mode On

Data format: [F0H] -> [7EH] -> [XnH] -> [09H] -> [01H] ->

[F7H]

F0H = Exclusive status
7EH = Universal Non-Realtime
7FH = ID of target device
09H = Sub-ID #1=General MIDI Message
01H = Sub-ID #2=General MIDI On
F7H = End of Exclusive
or
F0H = Exclusive status
7EH = Universal Non-Realtime
XnH = When received, n=0~F.
X = don’t care
09H = Sub-ID #1=General MIDI Message
01H = Sub-ID #2=General MIDI On
F7H = End of Exclusive
When the General MIDI mode ON message is received, the
MIDI system will be reset to its default settings.
This message requires approximately 50ms to execute, so
sufficient time should be allowed before the next message is
sent.
YDP-123 MSB LSB
P.C.#
Grand Piano 1 0 122 0
Grand Piano 2 0 112 0
E.Piano 1 0 122 5
E.Piano 2 0 122 4
Harpsichord 1 0 122 6
Harpsichord 2 0 123 6
Vibraphone 0 122 11
Church Organ 1 0 123 19
Church Organ 2 0 122 19
Strings 0 122 48
Data Transmission Reception
F8H Transmitted every
96 clocks Received as 96-clock tempo timing
when MIDI clock is set to External.
FAH Song start Song start
Not received when the MIDI clock is
set to Internal.
FCH Song stop Song stop
Not received when the MIDI clock is
set to Internal.
FEH Transmitted every
200 milliseconds
If a signal is not received via MIDI for
more than 400 milliseconds, the
same processing will take place for
All Sound Off, All Notes Off and Reset
All Controllers as when those signals
are received.