779-033a

779-034a

wq

763-083a

er

763-059

AE00895

FUSE REPLACEMENT(for EF4000DE/EF5200DE/EF6600DE/YG6600DE)

w

Be sure to use specified fuse. A wrong fuse will cause electrical system damage and A FIRE HAZ- ARD.

cC

Be sure the engine switch is turned off to prevent accidental short circuiting.

1.Loosen the control panel screws and then remove the control panel.

2.Replace the blown fuse with one of proper amper- age.

Specified fuse: 10A

NOTE:

If the fuse immediately blows again, consult a Yamaha dealer.

AE00501

G.F.C.I. RECEPTACLE TEST

(for YG4000D/YG5200D/YG6600D/YG6600DE)

1.Start the engine.

2.Turn the AC switch (N.F.B.) to the “ON” position.

3.Press the test button 1, then check the position of the reset button 2.

G.F.C.I. Reset

G.F.C.I. Receptacle

Button Position

Operation

after Test

 

 

 

Pop Out 3

Correct

 

 

Stay In 4

Incorrect

4.If G.F.C.I. operation is correct, push in the reset button.

If the G.F.C.I. operates incorrectly, consult a Yamaha dealer.

w

Do not operate the generator with a faulty G.F.C.I. circuit. Electric shock could occur. Have the generator repaired by a qualified mechanic.

– 35 –