TECHNICAL GUIDE

TECHNICAL GUIDE

SPLIT-SYSTEM HEAT PUMPS

10 SEER – R-22

MODELS:

10 SEER 50 HZ R22

H*RA018S78 THRU H*RA036S78 (1 PH) (1.5 THRU 3 NOMINAL TONS)

Due to continuous product improvement, specifications are subject to change without notice.

Visit us on the web at www.york.com

339293-YTG-C-0208

DESCRIPTION

The HRA Series condensing unit is the outdoor part of a ver- satile system of air conditioning. It is designed to be custom matched with one of UPG’s complete line of evaporator sec- tions, each designed to serve a specific function. Matching Air Handlers are available for upflow, downflow or horizontal applications to provide a complete system. Electric Heaters are available if required. Add-On coils are available for use with upflow, downflow or horizontal furnaces and air handlers.

FEATURES

QUALITY CONDENSER COILS - The coil is constructed of enhanced copper tube and aluminum fins.

COIL PROTECTION - Coils are protected from damage by a polymer mesh applied between the coil face, and a PVC coated steel coil guard.

PROTECTED COMPRESSOR - The compressor is inter- nally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the compressor if undesirable operating condi- tions occur. A liquid line filter-drier further protects the compressor.

DURABLE FINISH - Cabinet is made of pre-painted steel. The pre-treated flat galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. Special primer formulas and matted-textured finish insure less fading when exposed to sunlight.

LOWER INSTALLED COST - Installation time and costs are reduced by easy power and control wiring connections. Discharge line heat exchanger knockouts are provided, if required. Available in sweat connect models only. The unit contains enough refrigerant for matching indoor coils and 15 feet of interconnecting piping. The small base dimen- sion means less space is required on the ground or roof.

TOP DISCHARGE - The warm air from the top mounted fan is blown up away from the structure and any landscap- ing. This allows compact location on multi-unit applica- tions.

LOW OPERATING SOUND LEVEL - The upward air flow carries the normal operating noise up away from the living area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and com- pressor operating sounds.

LOW MAINTENANCE - Long life permanently lubricated motor-bearings need no annual servicing.

EASY SERVICE ACCESS - Fully exposed refrigerant con- nections, a single panel covering the electrical controls and the molex plug in the control box connecting the con- denser fan, make for easy servicing of the unit.

SECURED SERVICE VALVES - Secured re-usable ser- vice valves are provided on both the liquid and vapor sweat connections for ease of evacuating and charging.

FACTORY TESTED - to verify system operation and con- trol functioning before shipment.