York 10 SEER 50HZ R22 Accessories, Sound Ratings, Unit Model, Unitary Products Group

Models: 10 SEER 50HZ R22

1 8
Download 8 pages 29.43 Kb
Page 4
Image 4
ACCESSORIES

339293-YTG-C-0208

ACCESSORIES

Refer to Price Manual for specific model numbers.

Compressor Blanket - Designed to further reduce the nor- mal operating sound.

Hard Start Kit (Single Phase Units) - provides required starting torque for use with thermal expansion valve.

Outdoor Thermostat - 2TD06700124 - Consists of an adjustable outdoor thermostat and relay in a vented enclo- sure. It provides additional second stage control of the sup- plemental resistance heat.(Balance Point Control)

SOUND RATINGS

UNIT MODEL

(dBA)

 

 

018

76

 

 

024

78

 

 

030

82

 

 

036

82

 

 

* Rated in accordance with ARI 270-95 Standards.

TYPICAL INSTALLATION - H*RA018S78 THRU 036S78 (1 PH)

 

MINIMUM 18” SERVICE ACCESS

 

60” OVERHEAD

CLEARANCE ON ONE SIDE

THERMOSTAT TO FURNACE OR

 

AIR HANDLER

CLEARANCE

WEATHERPROOF

TERMINAL BLOCK

 

 

DISCONNECT

 

 

 

SWITCH

NEC CLASS 1 WIRING

 

 

NEC CLASS 2 WIRING

10” CLEARANCE COIL AREA SOUND RATINGS

TO INDOOR COIL

NOTE: ALL OUTDOOR WIRING MUST BE WEATHERPROOF.

SEAL OPENING(S) WITH

PERMAGUM OR EQUIVALENT

CONTROL ACCESS PANEL

TYPICAL FIELD WIRING - 1 PH APPLICATION (018S78 - 036S78)

ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES

POWER WIRING

230-1-50

24 VOLT CONTROL WIRING MINIMUM 18 GA. WIRE (NEC CLASS 2)

POWER WIRING

CONTROL WIRING

FACTORY WIRING

FURNACE OR AIR HANDLER TERMINAL BLOCK

CONTACTOR

TERMINALS

GND.

LUG

COIL

*TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT.

C Y R G W

Y R G W

*

CONDENSING UNIT

ROOM THERMOSTAT

 

ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.

4

Unitary Products Group

Page 4
Image 4
York 10 SEER 50HZ R22 specifications Accessories, Sound Ratings, Unit Model, Unitary Products Group