York 13 AND 14 SEER General Information, Inspection, Reference, Limitations, Air Temperature on

Models: 13 AND 14 SEER 12 10

1 12
Download 12 pages 8.73 Kb
Page 2
Image 2
GENERAL INFORMATION

035-13606-003 Rev. A (202)

GENERAL INFORMATION

These outdoor units are designed to be connected to a matching UPG indoor coil with sweat connection lines. These units are factory charged with refrigerant for a matching indoor coil plus 15 feet of field supplied line. The outside unit is designed to be placed alongside or at the back of the home, remote from the indoor coil. The outdoor unit has been factory run-tested and all components of the system are ready for easy, immediate installation.

INSPECTION

Check the unit thoroughly for shipping damage, Unusually rough handling during shipment may loosen fan motors, com- pressors, or other components. Be sure that the unit is ready to operate before installing it. If there is damage, file a claim with the shipper. See Form 50.15-NM for more information.

REFERENCE

Use this instruction in conjunction with the instructions for the appropriate indoor unit, air moving system and accessories.

Installer should pay particular attention to the words NOTE, CAUTION and WARNING.

NOTES are intended to clarify or make the installation easier.

CAUTIONS identify procedures which, if not followed care- fully, could result in personal injury, property damage or equipment damage.

WARNINGS are given to alert the installer that severe per- sonal injury, death or equipment damage may result if instal- lation procedures are not followed properly.

LIMITATIONS

The unit should be installed in accordance with all national and local codes and regulations which govern the installation of this type of equipment. In lieu of local codes, the equip- ment should be installed in accordance with National Electric Code, and in accordance with the recommendations made by the National Board of Fire Underwriters.

Limitations for the indoor unit, coil and appropriate accesso- ries must also be observed.

The outdoor unit must not be installed with any duct work in the air stream. The outdoor fan is the propeller type and is not designed to operate against any additional external static pressure.

The maximum and minimum conditions for operation must be observed to assure a system that will give maximum perfor- mance with minimum service.

The manufacturer is not responsible for the per- formance of a mismatched system. The outdoor unit must be installed with a compatible indoor unit as designated in the specification data or in the Directory of Certified Unitary Heat Pumps published by the Air Conditioning and Refrigera- tion Institute. Using unmatched components may not only affect the performance of the system, but may also void the warranty of the equipment.

Do not install any coil in a furnace which is to be operated during the heating season without attaching the refrigerant lines to the coil. Allowing the coil charge to enter the refrigerant lines pre- vents excessive refrigerant pressure build-up and possible coil damage.

Table 1: APPLICATION LIMITATIONS

Ambient Air Temperature

Air Temperature on

on Outdoor Coil

Indoor Coil

Min. °DB

Max. °DB

Min.

Max.

50

120

57

72

CHECK ELECTRICAL POWER SUPPLY

The electrical power should be checked to determine if ade- quate power is available, and near constant voltage can be maintained. If there is any question concerning the power supply, contact the local power company for corrections; oth- erwise, unsatisfactory performance may result.

SELECTING EQUIPMENT LOCATION

Several important factors must be considered before select- ing the site for the outdoor unit:

Distance to indoor coil

Proximity to the structure

Proximity to vents and exhaust systems

Ability to service

Sound transmission

Air circulation

Wind direction

Relationship between structure, sun, and unit

Distance from power source

Water drainage

Local codes

Locate the outdoor unit near enough to the indoor coil vicinity to eliminate lengthy refrigerant line runs. Do not locate the outdoor unit so it discharges air under eaves or gutters. Rain or snow melt-off should not be able to run off a roof and down upon the unit. Be sure vents are not located upwind from the outdoor unit.

2

Unitary Products Group

Page 2
Image 2
York 13 AND 14 SEER General Information, Inspection, Reference, Application Limitations, Check Electrical Power Supply