LOW VOLTAGE
Control wiring may vary depending upon the type of thermo- stat and furnace being connected.
Low voltage wiring diagrams can be found with the furnace or air conditioning blower package installation instructions.
1.Route the low voltage cable through the fingered bush- ing in the low voltage junction box. See Figures 9, 10 & 11.
2.Using wire nuts, connect the low voltage wiring within the low voltage box.
3.A minimum of 19 AWG wire must be used in connecting the low voltage control wiring between the outdoor unit, air handler thermostat, and outdoor thermostat. For longer low voltage control wiring lengths, consult the N.E.C.
Connect thermostat and control package wiring as shown in Figure 12 and per the instructions packed with those pieces.
START RELAY | CONTACTOR | |
| ||
(Not on all Models) |
| |
DUAL |
| |
RUN/FAN | FAN | |
CAPACITOR | ||
MOTOR | ||
| ||
| PLUG | |
START |
| |
CAPACITOR | LOW | |
(Not on all Models) | ||
| VOLTAGE | |
| BOX | |
GROUND | “FINGERED” | |
BUSHING | ||
LUG | ||
| ||
| REVERSIBLE HIGH VOLTAGE | |
| CONDUIT PLATE | |
FIGURE 3 : Typical Condensing Unit Control Box (Start Components Shown) |
| START RELAY | |
| CONTACTOR | |
| DUAL | |
| RUN/FAN | |
| CAPACITOR | |
LOW |
| |
VOLTAGE | FAN | |
BOX | ||
MOTOR | ||
| ||
| PLUG | |
“FINGERED” |
| |
BUSHING |
| |
GROUND LUG | ADJUSTABLE HIGH VOLTAGE | |
CONDUIT PLATE | ||
|
FIGURE 4 : Typical Condensing Unit Control Box (Start Components Shown)
Unitary Products Group | 7 |