036-21630-001-B-0904

TABLE OF CONTENTS

DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 PRODUCT NOMENCLATURE . . . . . . . . . . . . . . . . . 3 FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 FACTORY-INSTALLED OPTIONS . . . . . . . . . . . . . 12 FIELD-INSTALLED ACCESSORIES . . . . . . . . . . . 13 GUIDE SPECIFICATIONS . . . . . . . . . . . . . . . . . . . 29

Fig. #

LIST OF FIGURES

Pg. #

1 UNIT CUTAWAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 2 TYPICAL FIELD POWER & CONTROL WIRING . . . . . 23 3 UNIT DIMENSIONS - FRONT VIEW . . . . . . . . . . . . . . 24 4 UNIT WITH ECONOMIZER RAINHOOD . . . . . . . . . . . 24

5 UNIT WITH FIXED OUTDOOR AIR/MOTORIZED DAMP- ER RAINHOOD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

6 UNIT DIMENSIONS (REAR VIEW) . . . . . . . . . . . . . . . 25 7 DISCONNECT/BLOWER ACCESS LOCATION. . . . . . 26 8 TYPICAL APPLICATIONS . . . . . . . . . . . . . . . . . . . . . . 27 9 FOUR AND SIX POINT LOADING . . . . . . . . . . . . . . . . 28 10 ROOF CURB DIMENSIONS . . . . . . . . . . . . . . . . . . . . 29

Tbl. #

LIST OF TABLES

Pg. #

1 SOUND POWER RATING . . . . . . . . . . . . . . . . . . . . . . 15 2 CAPACITY RATINGS . . . . . . . . . . . . . . . . . . . . . . . . . 15 3 BP072 COOLING CAPACITIES (6 TON) . . . . . . . . . . 16 4 BP072 HEATING CAPACITIES . . . . . . . . . . . . . . . . . . 18

5 SUPPLY AIR BLOWER PERFORMANCE (6 TON BELT DRIVE) - SIDE DUCT APPLICATION . . . . . . . . . . . . . 18

6 BELT DRIVE BLOWER MOTOR AND DRIVE DATA. . 19 7 STATIC RESISTANCES . . . . . . . . . . . . . . . . . . . . . . . 19 8 ELECTRIC HEATER CFM LIMITATIONS . . . . . . . . . . 19

9 BP 072 ELECTRICAL DATA BELT DRIVE WITHOUT POWERED CONVENIENCE OUTLET . . . . . . . . . . . . 20

10 BP 072 ELECTRICAL DATA BELT DRIVE WITH POWERED CONVENIENCE OUTLET . . . . . . . . . . . . 21

11 PHYSICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 12 ELECTRIC HEAT CORRECTION FACTORS . . . . . . 22 13 VOLTAGE LIMITATIONS . . . . . . . . . . . . . . . . . . . . . . 22 14 UTILITIES ENTRY . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 15 MINIMUM CLEARANCES . . . . . . . . . . . . . . . . . . . . . . 26

16BP 4 POINT LOADS WEIGHT DISTRIBUTION . . . . . 28

17BP 6 POINT LOADS WEIGHT DISTRIBUTION . . . . . 28

18 CENTER OF GRAVITY . . . . . . . . . . . . . . . . . . . . . . . . 28 19 OPERATING WEIGHTS (LBS.) . . . . . . . . . . . . . . . . . . 28

2

Unitary Products Group

Page 2
Image 2
York BP 072 warranty Table of Contents

BP 072 specifications

The York BP 072 is a prominent model within the York line of rooftop units. Renowned for its efficiency and robust performance, the BP 072 is designed to cater to the needs of commercial applications where reliable heating and cooling are paramount. With a focus on energy efficiency, this model offers optimal performance while minimizing energy consumption, making it a suitable choice for businesses aiming to reduce operational costs.

One of the standout features of the York BP 072 is its advanced scroll compressor technology. This technology not only enhances the unit's efficiency but also ensures quieter operation, thus creating a more comfortable environment for occupants. The compressor's design helps reduce vibration, which contributes to the overall longevity of the unit.

In terms of thermal performance, the BP 072 is engineered with a high-efficiency coil design that maximizes heat exchange. This design plays a crucial role in delivering superior cooling and heating capabilities throughout the year. Furthermore, the unit comes equipped with multiple stages of heating and cooling, ensuring precise temperature control and comfort, regardless of the weather outside.

The BP 072 benefits from York’s commitment to sustainability, featuring environmentally friendly refrigerants that align with modern environmental regulations. The use of these refrigerants not only provides minimal ecological impact but also contributes to energy efficiency, addressing both operational costs and environmental concerns.

Another characteristic that sets the York BP 072 apart is its user-friendly control system. The unit includes an integrated microprocessor-based control that streamlines operation and monitoring. This feature allows facility managers to easily adjust settings, enabling the unit to operate efficiently based on current demand and occupancy levels.

Ease of maintenance is another significant aspect of the BP 072. Designed with accessible components, routine upkeep is simplified, allowing technicians to perform inspections and repairs with minimal disruption to building operations. This focus on serviceability not only extends the life of the unit but also ensures continuous performance.

Overall, the York BP 072 stands out as a reliable and efficient solution for commercial heating and cooling needs. Its advanced features, energy-efficient technologies, and user-friendly characteristics make it an ideal choice for businesses looking to manage their environment effectively while minimizing costs. Whether for new construction or replacement of existing systems, the York BP 072 is a strong contender in today’s competitive market.