246723-YTG-J-1006

Additional R-410A Charge / TXV Size for Various Matched Systems

Outdoor Unit

CZB01811

CZB02411

CZB03011

CZB03611

CZB04211

CZB04811

CZB06011

Unit Orifice (s)

1TVM901

1TVM903

1TVM903

1TVM903

1TVM904

1TVM905

1TVM905

1TVM4C1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory R-410A Charge, lbs-oz

5-13

6-4

7-4

6-4

8-13

8-12

13-9

 

 

 

 

 

 

 

 

Indoor Coil1,2

 

 

Additional Charge, Oz

 

 

G1NA030S17K

5

6

3

G1NA030S21M

5

6

3

G1NA036S17J

5

6

3

G1NA036S21C

5

6

3

G1NA036S17L

3

G1NA042S24W

6

G1NA048S21D

3

G1NA060S24T

6

12

G1FA/G1UA024S14,17

5

G1FA/G1UA030S14

5

3

G1FA/G1UA036S14

5

6

3

G1FA/G1UA036S17,21

5

6

3

G1FA/G1UA048S17

3

3

G1FA/G1UA048S21

3

3

G1FA/G1UA060S21,24

6

12

4

F*RP024/F*FP024

5

F*RP030/F*FP030

6

3

F*RP036/F*FP036

3

3

F*RP042/F*FP042

3

F*RP045/F*FP045

6

F*FP048

6

F*FP060

F*FV060

12

4

G4FD024H14,17

5

G4FD030H17

5

6

3

G4FD035H14

5

6

3

G4FD036H17

5

6

3

3

G4FD036H21

3

3

G4FD042H21

3

3

G4FD046H17

3

3

G4FD048H21,24

3

6

G4FD060H24

12

4

G4FD061H24

12

4

G4FA024S14,17

5

G4FA030S14

5

G4FA036S14

5

6

3

G4FA036S17,21

5

6

3

G4FA048S17

3

3

G4FA048S21

3

3

G4FA060S21,24

6

12

4

FOOTNOTES:

 

 

 

 

 

 

 

1Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224.

2PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.

PROCEDURES:

1.Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of intercon- necting line tubing.

2.Verify the TXV and additional charge required for specific evaporator coil in the system using the above table.

3.Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the Physical and Electri- cal Data Table.

4.Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator + adder for line set.