Additional
Outdoor Unit | CZB01811 | CZB02411 | CZB03011 | CZB03611 | CZB04211 | CZB04811 | CZB06011 | |
Unit Orifice (s) | 1TVM901 | 1TVM903 | 1TVM903 | 1TVM903 | 1TVM904 | 1TVM905 | 1TVM905 | |
1TVM4C1 | ||||||||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
Factory | ||||||||
|
|
|
|
|
|
|
| |
Indoor Coil1,2 |
|
| Additional Charge, Oz |
|
| |||
G1NA030S17K | 5 | 6 | 3 | – | – | – | – | |
G1NA030S21M | 5 | 6 | 3 | – | – | – | – | |
G1NA036S17J | 5 | 6 | 3 | – | – | – | – | |
G1NA036S21C | 5 | 6 | 3 | – | – | – | – | |
G1NA036S17L | – | – | – | 3 | – | – | – | |
G1NA042S24W | – | – | – | – | 6 | – | – | |
G1NA048S21D | – | – | – | 3 | – | – | – | |
G1NA060S24T | – | – | – | – | 6 | 12 | – | |
G1FA/G1UA024S14,17 | 5 | – | – | – | – | – | – | |
G1FA/G1UA030S14 | 5 | – | 3 | – | – | – | – | |
G1FA/G1UA036S14 | 5 | 6 | 3 | – | – | – | – | |
G1FA/G1UA036S17,21 | 5 | 6 | 3 | – | – | – | – | |
G1FA/G1UA048S17 | – | – | 3 | 3 | – | – | – | |
G1FA/G1UA048S21 | – | – | 3 | 3 | – | – | – | |
G1FA/G1UA060S21,24 | – | – | – | – | 6 | 12 | 4 | |
F*RP024/F*FP024 | 5 | – | – | – | – | – | – | |
F*RP030/F*FP030 | – | 6 | 3 | – | – | – | – | |
F*RP036/F*FP036 | – | – | 3 | 3 | – | – | – | |
F*RP042/F*FP042 | – | – | – | 3 | – | – | – | |
F*RP045/F*FP045 | – | – | – | – | 6 | – | – | |
F*FP048 | – | – | – | – | 6 | – | – | |
F*FP060 | – | – | – | – | – | – | – | |
F*FV060 | – | – | – | – | – | 12 | 4 | |
G4FD024H14,17 | 5 | – | – | – | – | – | – | |
G4FD030H17 | 5 | 6 | 3 | – | – | – | – | |
G4FD035H14 | 5 | 6 | 3 | – | – | – | – | |
G4FD036H17 | 5 | 6 | 3 | 3 | – | – | – | |
G4FD036H21 | – | – | 3 | 3 | – | – | – | |
G4FD042H21 | – | – | 3 | 3 | – | – | – | |
G4FD046H17 | – | – | 3 | 3 | – | – | – | |
G4FD048H21,24 | – | – | – | 3 | 6 | – | – | |
G4FD060H24 | – | – | – | – | – | 12 | 4 | |
G4FD061H24 | – | – | – | – | – | 12 | 4 | |
G4FA024S14,17 | 5 | – | – | – | – | – | – | |
G4FA030S14 | 5 | – | – | – | – | – | – | |
G4FA036S14 | 5 | 6 | 3 | – | – | – | – | |
G4FA036S17,21 | 5 | 6 | 3 | – | – | – | – | |
G4FA048S17 | – | – | 3 | 3 | – | – | – | |
G4FA048S21 | – | – | 3 | 3 | – | – | – | |
G4FA060S21,24 | – | – | – | – | 6 | 12 | 4 | |
FOOTNOTES: |
|
|
|
|
|
|
|
1Systems matched with furnace or air handlers not equipped with
2PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.
PROCEDURES:
1.Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of intercon- necting line tubing.
2.Verify the TXV and additional charge required for specific evaporator coil in the system using the above table.
3.Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the Physical and Electri- cal Data Table.
4.Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator + adder for line set.
4 | Unitary Products Group |