360101-XTG-B-0508

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TABLE 3: COOLING CAPACITIES - 2-1/2 TON (DEB030)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE

 

 

 

 

 

 

 

 

 

AIR ON INDOOR COIL

 

 

 

 

 

 

 

 

 

OF AIR ON

 

 

750 CFM

 

 

875 CFM

 

 

1,000 CFM

 

 

1,125 CFM

 

 

1,250 CFM

 

 

 

 

WB °F

 

 

WB °F

 

 

WB °F

 

 

WB °F

 

 

WB °F

 

 

OUTDOOR COIL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

67

62

57

72

67

62

57

72

67

62

57

72

67

62

57

72

67

62

57

 

 

 

Net Cap

 

32.3

29.8

27.5

28.1

32.6

30.1

27.8

28.4

33.0

30.4

28.1

28.7

33.5

30.9

28.4

29.1

33.9

31.3

28.8

29.5

 

 

 

 

MBH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total Power

 

2.94

2.92

2.83

2.81

3.02

3.00

2.90

2.88

3.10

3.08

2.98

2.96

3.20

3.18

3.08

3.06

3.31

3.28

3.18

3.16

 

 

 

Input kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

86

18.2

23.6

27.5

28.1

20.1

25.8

27.8

28.4

21.9

28.0

28.1

28.7

23.3

29.6

28.4

29.1

24.8

31.3

28.8

29.5

85 °F

 

 

 

 

83

16.1

21.4

25.5

26.3

17.5

23.3

26.8

27.5

19.0

25.1

28.1

28.7

20.0

26.4

28.4

29.1

21.1

27.7

28.8

29.5

 

 

1

 

 

80

14.0

19.3

23.3

24.1

15.0

20.7

25.1

25.9

16.0

22.2

26.8

27.7

16.7

23.1

27.8

28.6

17.3

24.0

28.8

29.5

 

 

 

 

 

77

11.8

17.2

21.2

22.0

12.5

18.2

22.5

23.4

13.1

19.3

23.9

24.8

13.4

19.7

24.5

25.3

13.6

20.2

25.1

25.8

 

 

 

 

 

74

9.7

15.0

19.1

19.9

10.0

15.7

20.0

20.9

10.2

16.3

21.0

21.9

10.1

16.4

21.2

22.0

9.9

16.5

21.4

22.1

 

 

 

 

 

71

-

12.9

16.9

17.7

-

13.2

17.5

18.3

-

13.4

18.0

19.0

-

13.1

17.9

18.7

-

12.8

17.7

18.4

 

 

 

 

 

68

-

10.8

14.8

15.6

-

10.6

15.0

15.8

-

10.5

15.1

16.1

-

9.8

14.5

15.3

-

9.1

13.9

14.6

 

 

 

 

Net Cap

 

29.1

27.5

24.4

24.8

30.2

28.6

25.3

25.7

31.3

29.7

26.2

26.7

30.9

29.3

25.9

26.4

30.5

28.9

25.6

26.0

 

 

 

 

MBH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total Power

 

3.17

3.11

3.04

3.03

3.24

3.17

3.10

3.09

3.30

3.23

3.16

3.15

3.43

3.36

3.29

3.27

3.56

3.49

3.41

3.39

 

 

 

Input kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

86

17.5

22.2

24.4

24.8

19.5

24.7

25.3

25.7

21.6

27.2

26.2

26.7

23.1

28.1

25.9

26.4

24.6

28.9

25.6

26.0

95 °F

 

 

 

 

83

15.4

20.1

24.1

23.9

17.0

22.2

25.2

25.3

18.7

24.3

26.2

26.7

19.8

25.7

25.9

26.4

20.9

27.0

25.6

26.0

 

 

1

 

 

80

13.2

18.0

22.0

21.8

14.5

19.7

24.1

23.8

15.8

21.4

26.2

25.9

16.5

22.4

25.9

26.0

17.2

23.3

25.6

26.0

 

 

 

 

 

77

11.1

15.8

19.9

19.6

12.0

17.2

21.6

21.3

12.8

18.5

23.3

23.0

13.1

19.0

22.6

22.6

13.4

19.6

21.8

22.3

 

 

 

 

 

74

9.0

13.7

17.7

17.5

9.4

14.6

19.1

18.8

9.9

15.6

20.4

20.1

9.8

15.7

19.2

19.3

9.7

15.9

18.1

18.6

 

 

 

 

 

71

-

11.6

15.6

15.3

-

12.1

16.5

16.3

-

12.7

17.5

17.2

-

12.4

15.9

16.0

-

12.1

14.4

14.8

 

 

 

 

 

68

-

9.4

13.5

13.2

-

9.6

14.0

13.7

-

9.7

14.6

14.3

-

9.1

12.6

12.7

-

8.4

10.6

11.1

 

 

 

 

Net Cap

 

26.7

24.8

22.2

22.3

27.8

25.8

23.1

23.2

28.9

26.8

24.0

24.1

28.6

26.5

23.7

23.9

28.3

26.3

23.5

23.6

 

 

 

 

MBH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total Power

 

3.38

3.28

3.22

3.22

3.45

3.35

3.29

3.28

3.52

3.42

3.36

3.35

3.66

3.55

3.49

3.48

3.79

3.68

3.62

3.61

 

 

 

Input kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

86

16.5

21.3

22.2

22.3

18.5

23.4

23.1

23.2

20.5

25.6

24.0

24.1

22.0

25.9

23.7

23.9

23.5

26.3

23.5

23.6

105 °F

 

 

 

 

83

14.4

19.2

22.0

21.8

16.0

21.2

23.0

22.9

17.6

23.3

24.0

24.1

18.7

24.3

23.7

23.9

19.7

25.3

23.5

23.6

 

 

1

 

 

80

12.3

17.0

19.8

19.6

13.5

18.7

21.8

21.6

14.7

20.4

23.8

23.5

15.4

21.3

23.6

23.6

16.0

22.2

23.5

23.6

 

 

 

 

 

77

10.1

14.9

17.7

17.5

10.9

16.2

19.3

19.0

11.8

17.5

20.9

20.6

12.0

18.0

20.3

20.3

12.3

18.5

19.8

19.9

 

 

 

 

 

74

8.0

12.7

15.6

15.3

8.4

13.7

16.8

16.5

8.9

14.6

17.9

17.7

8.7

14.7

17.0

16.9

8.6

14.8

16.0

16.2

 

 

 

 

 

71

-

10.6

13.4

13.2

-

11.1

14.2

14.0

-

11.7

15.0

14.8

-

11.4

13.7

13.6

-

11.0

12.3

12.5

 

 

 

 

 

68

-

8.5

11.3

11.1

-

8.6

11.7

11.5

-

8.7

12.1

11.9

-

8.0

10.3

10.3

-

7.3

8.6

8.7

 

 

 

 

Net Cap

 

24.3

22.0

20.0

19.8

25.4

22.9

20.8

20.7

26.4

23.9

21.7

21.5

26.2

23.7

21.6

21.4

26.1

23.6

21.4

21.3

 

 

 

 

MBH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total Power

 

3.58

3.45

3.41

3.41

3.66

3.52

3.48

3.48

3.74

3.60

3.56

3.56

3.89

3.74

3.69

3.69

4.03

3.87

3.83

3.83

 

 

 

Input kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

86

15.6

20.3

20.0

19.8

17.5

22.1

20.8

20.7

19.5

23.9

21.7

21.5

20.9

23.7

21.6

21.4

22.3

23.6

21.4

21.3

115 °F

 

 

 

 

83

13.4

18.2

19.8

19.6

15.0

20.3

20.7

20.6

16.5

22.3

21.7

21.5

17.6

23.0

21.6

21.4

18.6

23.6

21.4

21.3

 

 

1

 

 

80

11.3

16.1

17.7

17.5

12.5

17.7

19.5

19.3

13.6

19.4

21.3

21.1

14.2

20.3

21.4

21.2

14.9

21.1

21.4

21.3

 

 

 

 

 

77

9.1

13.9

15.5

15.3

9.9

15.2

17.0

16.8

10.7

16.5

18.4

18.2

10.9

16.9

18.1

17.9

11.1

17.4

17.7

17.6

 

 

 

 

 

74

7.0

11.8

13.4

13.2

7.4

12.7

14.4

14.2

7.8

13.6

15.5

15.3

7.6

13.6

14.7

14.6

7.4

13.7

14.0

13.8

 

 

 

 

 

71

-

9.6

11.2

11.1

-

10.1

11.9

11.7

-

10.6

12.6

12.4

-

10.3

11.4

11.2

-

10.0

10.2

10.1

 

 

 

 

 

68

-

7.5

9.1

8.9

-

7.6

9.4

9.2

-

7.7

9.7

9.5

-

7.0

8.1

7.9

-

6.2

6.5

6.4

 

 

 

 

Net Cap

 

21.9

19.2

17.8

17.4

22.9

20.1

18.6

18.2

23.9

21.0

19.4

19.0

23.9

21.0

19.4

18.9

23.9

20.9

19.4

18.9

 

 

 

 

MBH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total Power

 

3.8

3.6

3.6

3.6

3.9

3.7

3.7

3.7

4.0

3.8

3.8

3.8

4.1

3.9

3.9

3.9

4.3

4.1

4.0

4.0

 

 

 

Input kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

86

14.6

19.4

17.8

17.4

16.5

20.8

18.6

18.2

18.4

22.2

19.4

19.0

19.8

21.6

19.4

18.9

21.2

20.9

19.4

18.9

125 °F

 

 

 

 

83

12.5

17.2

17.6

17.5

14.0

19.3

18.5

18.2

15.5

21.3

19.4

19.0

16.5

21.6

19.4

18.9

17.4

21.9

19.4

18.9

 

 

1

 

 

80

10.3

15.1

15.5

15.3

11.4

16.7

17.2

17.0

12.6

18.4

18.9

18.7

13.1

19.2

19.1

18.8

13.7

20.1

19.4

18.9

 

 

 

 

 

77

8.2

13.0

13.3

13.2

8.9

14.2

14.7

14.5

9.6

15.5

16.0

15.8

9.8

15.9

15.8

15.5

10.0

16.3

15.6

15.2

 

 

 

 

 

74

6.0

10.8

11.2

11.1

6.4

11.7

12.1

12.0

6.7

12.6

13.1

12.9

6.5

12.6

12.5

12.2

6.3

12.6

11.9

11.5

 

 

 

 

 

71

-

8.7

9.1

8.9

-

9.2

9.6

9.4

-

9.6

10.1

10.0

-

9.3

9.2

8.9

-

8.9

8.2

7.7

 

 

 

 

 

68

-

6.5

6.9

6.8

-

6.6

7.1

6.9

-

6.7

7.2

7.0

-

5.9

5.8

5.5

-

5.2

4.5

4.0

1.These are net capacity ratings. The indoor blower motor heat has already been subtracted from the gross cooling capacity

ALL SENSIBLE CAPACITIES

6

Johnson Controls Unitary Products

Page 6
Image 6
York D2EB030 manual Cooling Capacities 2-1/2 TON DEB030, Outdoor Coil

D2EB030 specifications

The York D2EB030 is a prominent model in the realm of commercial climate control systems, specifically designed to cater to medium to large-scale applications. This equipment stands out due to its high efficiency and reliability, ensuring optimal thermal comfort in various settings, from office buildings to warehouses.

One of the main features of the York D2EB030 is its capacity. With a nominal cooling capacity of around 30 tons, it is well-suited for substantial cooling demands. This makes it an excellent choice for facilities that require consistent and effective temperature management. Additionally, it offers variable refrigerant flow (VRF) operation, which allows for simultaneous heating and cooling in different zones, providing enhanced comfort and flexibility.

The D2EB030 is equipped with advanced inverter technology. This feature allows the compressor to modulate its speed based on the cooling or heating needs of the environment, leading to significant energy savings. By adjusting the refrigerant flow and maintaining more stable indoor temperatures, the inverter-driven compressor reduces operational costs and energy consumption compared to traditional systems.

Additionally, the unit boasts a range of control options. It can be integrated with smart building management systems, allowing for remote monitoring and control through mobile devices or computers. This connectivity enables facility managers to optimize operation schedules, perform maintenance checks, and respond quickly to any issues, enhancing overall efficiency.

In terms of build quality, the York D2EB030 showcases robust construction, designed to withstand the rigors of commercial use. Its corrosion-resistant materials ensure longevity and reduce maintenance requirements. The system is also designed with sound-dampening features, resulting in quieter operation—a crucial aspect in noise-sensitive environments.

Among its environmental considerations, the unit utilizes refrigerants that are compliant with global regulations, contributing to lower greenhouse gas emissions. Moreover, its design promotes higher energy efficiency ratios (EER) and seasonal energy efficiency ratios (SEER), which are critical for reducing the overall carbon footprint.

In summary, the York D2EB030 stands out in the market for its combination of robust features, advanced technologies, and energy efficiency, making it a top choice for commercial climate control solutions. With its capacity, smart technology integration, and environmental considerations, this model is tailored to meet the dynamic needs of modern facilities while ensuring cost-effectiveness and sustainability.