530.26-TG3YI

BLOWER MOTOR AND DRIVE DATA

 

 

 

BLOWER

MOTOR1

 

ADJUSTABLE 2

 

FIXED

 

BELT (NOTCHED)

UNIT

 

 

 

 

MOTOR PULLEY

BLOWER PULLEY

 

 

 

 

RANGE

 

 

 

PITCH

 

 

PITCH

 

 

PITCH

 

 

SIZE

 

 

FRAME

EFF.

BORE

DESIG-

BORE

DESIG-

DESIG-

 

 

(RPM)

kW/HP

DIA.

DIA.

LENGTH

QTY

 

 

 

 

 

SIZE

(%)

(mm/in.)

(mm/in.)

NATION

(mm / in.)

(mm/in.)

NATION

(mm/in.)

NATION

 

 

 

180

845-1040

3.0 / 4.0

184T

84

109-135

29 / 11¤8

1VP56

188 / 7.4

25 / 1

BK80

1773 / 69.8

BX68

1

STD.

 

4.3-5.3

DRIVE

 

240

765-905

5.6 / 7.5

213T

87

140-165

35 / 13¤8

1VP68

264 / 10.4

30 / 13¤16

BK110

2103 / 82.8

BX81

1

 

 

5.5-6.5

HIGH

 

180

1030-1240

3.0 / 4.0

184T

84

124-150

29 / 11¤8

1VP62

175 / 6.9

25 / 1

BK75

1773 / 69.8

BX68

1

 

4.9-5.9

SPEED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

147-178

35 / 13¤8

 

 

30 / 13¤16

 

 

 

 

DRIVE

 

240

895-1080

5.6 / 7.5

213T

87

1VP75

239 / 9.4

BK100

2103 / 82.8

BX81

1

 

5.8-7.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1All motors are totally enclosed, fan cooled (TEFC), 1450 RPM with solid bases and a 1.15 service factor.

 

 

 

 

 

 

2Do NOT close this pulley below the minimum number of turns open.

 

 

 

 

 

 

 

 

 

STATIC RESISTANCES*

 

 

 

 

EXTERNAL STATIC [RESSURE DRP RESISTANCE, Pa/IWG

 

 

 

 

 

 

 

 

 

 

DESCRIPTION

 

 

 

M3/S / CFM

 

 

 

 

 

 

MODEL 180

 

 

MODEL 240

 

 

 

 

 

 

 

 

 

 

 

 

 

2.1 / 4500

2.8 / 6000

3.4 / 7200

2.8 / 6000

3.8 / 8000

4.4 / 9400

WET COIL

 

24.8 / 0.1

24.8 / 0.1

24.8 / 0.1

24.8 / 0.1

24.8 / 0.1

24.8 / 0.1

 

 

 

 

 

 

 

 

 

 

 

18 kW

24.8 / 0.1

24.8 / 0.1

24.8 / 0.1

24.8 / 0.1

24.8 / 0.1

24.8 / 0.1

ELECTRIC HEAT

 

 

 

 

 

 

 

 

 

36 kW

24.8 / 0.1

50.0 / 0.2

74.4 / 0.3

24.8 / 0.1

50.0 / 0.2

74.4 / 0.3

OPTIONS

 

 

 

 

 

 

 

 

 

54 kW

50.0 / 0.2

74.4 / 0.3

99.2 / 0.4

50.0 / 0.2

74.4 / 0.3

99.2 / 0.4

 

 

 

 

 

 

 

 

 

 

 

 

 

72 kW

50.0 / 0.2

99.2 / 0.4

149.0 / 0.6

50.0 / 0.2

99.2 / 0.4

149.0 / 0.6

 

 

 

 

 

 

 

 

ECONOMIZER OPTION

24.8 / 0.1

24.8 / 0.1

24.8 / 0.1

24.8 / 0.1

24.8 / 0.1

24.8 / 0.1

 

 

 

 

 

 

 

 

HORIZONTAL DUCT

 

50.0 / 0.2

74.4 / 0.3

124.0 / 0.5

50.0 / 0.2

74.4 / 0.3

124.0 / 0.5

CONNECTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Deduct these resistance values from the available unit ESP values listed in the respective blower performance table except for Horizontal Duct Connections. Add the Horizontal Duct Connection values due to less airflow resistance.

12

Unitary Products Group

Page 12
Image 12
York D3CE, D3CG manual Blower Motor and Drive Data, Static Resistances

D3CG, D3CE specifications

York D3CE and D3CG are innovative air-cooled chillers developed to address the growing demands for energy-efficient cooling solutions in commercial and industrial settings. These models are part of York's comprehensive range of HVAC products, showcasing advanced engineering and cutting-edge technologies designed to optimize performance while reducing operational costs.

One of the standout features of the York D3CE and D3CG series is their high efficiency. These chillers utilize a variable speed drive (VSD) technology that allows the compressor to adjust its speed according to the cooling load. This capability enhances energy efficiency, particularly in varying load conditions, and can lead to substantial energy savings compared to traditional fixed-speed chillers.

In terms of environmentally friendly refrigerants, both the D3CE and D3CG models are designed to operate with refrigerants that have low global warming potential (GWP). This aspect not only supports sustainability initiatives but also aligns with international regulations aimed at reducing greenhouse gas emissions. This makes them an appealing choice for organizations committed to minimizing their environmental impact.

The York D3CE and D3CG chillers are engineered to ensure quiet operation, making them suitable for noise-sensitive applications such as urban environments, hospitals, and educational institutions. Sound-dampening technologies are integrated into the design to minimize operational noise, thus preserving the quality of the surrounding environment.

Another significant characteristic is the advanced control system tailored for these chillers. The intuitive controls interface allows for easy monitoring and adjustment of operating parameters, enabling facilities managers to optimize performance and maintain effective cooling without extensive training.

Durability and reliability are also hallmarks of the D3CE and D3CG series. Constructed with high-quality materials and robust components, these models are engineered to withstand harsh operating conditions and deliver consistent performance over time. Regular maintenance can be managed efficiently thanks to accessible service points, ensuring that these chillers can serve their intended lifespan and beyond.

In summary, the York D3CE and D3CG series stands out in the crowded HVAC market due to their high efficiency, environmentally friendly design, quiet operation, advanced control capabilities, and rugged reliability. These features make them a prudent choice for organizations looking to enhance their cooling systems while adhering to environmental and economic sustainability goals.