530.26-TG3YI

ELECTRICAL DATA - Units With Supplemental Electric Heating

 

POWER

 

HEATER OPTION

 

MINIMUM

 

MINIMUM

UNIT

SUPPLY

 

OUTPUT

 

 

CIRCUIT

MAXIMUM

2

 

 

 

 

 

1

WIRE SIZE

SIZE

(VOLTS)

MODEL

kW

STAGES

AMPS

AMPACITY

FUSE SIZE

(mm2/AWG)

 

 

 

 

 

 

(AMPS)

 

 

 

 

E018

11.3

1

17.1

47.0

60

10 / 8

 

380-3+N-50

E036

22.6

2

34.3

53.6

60

16 / 6

 

E054

33.8

2

51.4

75.0

80

25 / 4

 

 

180

 

E072

45.1

2

68.6

96.5

100

35 / 2

 

E018

13.5

1

18.7

47.0

60

10 / 8

 

 

 

415-3+N-50

E036

26.9

2

37.4

57.5

60

16 / 6

 

E054

40.4

2

56.2

80.9

90

25 / 4

 

 

 

 

E072

53.8

2

74.9

104.0

110

35 / 2

 

 

E018

11.3

1

17.1

59.7

70

16 / 6

 

380-3+N-50

E036

22.6

2

34.3

59.7

70

16 / 6

 

E054

33.8

2

51.4

78.9

80

25 / 4

 

 

240

 

E072

45.1

2

68.6

100.0

110

35 / 2

 

E018

13.5

1

18.7

59.7

70

16 / 6

 

 

 

415-3+N-50

E036

26.9

2

37.4

61.4

70

16 / 6

 

E054

40.4

2

56.2

84.8

90

25 / 4

 

 

 

 

E072

53.8

2

74.9

108.0

110

50 / 2

NOTES:

1. Slow blow type fuse.

 

2. Based on 105°C copper conductors.

PHYSICAL DATA

 

COMPONENT DESCRIPTION

UNIT SIZE (MBH)

 

180

240

 

 

 

SUPPLY AIR

CENTRIFUGAL BLOWER

DIA. x WD. (mm)

381 x 381

457 x 381

DIA. x WD. (in.)

15 x 15

18 x 15

BLOWER

 

FAN MOTOR

kW / HP

3.7 / 5

5.6 / 7.5

 

INDOOR

ROWS DEEP

 

3

3

FINS PER 25mm (1 in.)

 

13.5

13.5

COIL

 

FACE AREA

m2 / Ft.2

1.45 / 15.5

1.92 / 20.5

 

OUTDOOR

PROPELLER DIA.

mm / in.

762 / 30 (ea.)

762 / 30 (ea.)

FAN MOTOR

kW / HP

0.7 / 1 (ea.)

0.7 / 1 (ea.)

FANS

NOMINAL AIRFLOW

m3 / s

2.83 (ea.)

3.78 (ea.)

(Two Per Unit)

 

 

 

CFM

6000 (ea.)

8000 (ea.)

 

 

OUTDOOR

ROWS DEEP

 

2

2

FINS PER 25mm (1 in.)

 

13

20

COIL

 

FACE AREA

m2 / Ft.2

3.35 / 36.0

4.02 / 43.3

 

COMPRESSOR

TANDEM (10 TON NOMINAL CAPACITY)

1*

2

(Qty. Per Unit)

HERMETIC (5 TON NOMINAL CAPACITY)

1

-

 

QUANTITY PER UNIT

406 x 508 x 51 (mm)

-

4

 

16 x 20 x 2 (in.)

 

 

 

 

AIR

QUANTITY PER UNIT

406 x 635 x 51 (mm)

-

4

16 x 25 x 2 (in.)

FILTERS

 

 

 

QUANTITY PER UNIT

457 x 610 x 51 (mm)

5

-

 

 

18 x 24 x 2 (in.)

 

 

 

 

 

TOTAL FACE AREA

m2 / Ft.2

1.40 / 15.0

1.87 / 20.0

CHARGE

REFRIGERANT 22

SYS. #1 ( kg. / lbs.)

7.94 / 17.5

8.16 / 18.0

SYS. #2 (kg. / lbs.)

3.86 / 8.5

8.16 / 18.0

 

 

*This compressor will be energized first.

WEIGHTS (kg. / lbs.)

 

D*CE UNITS

 

180

866 / 1910

BASIC

240

957 / 2110

UNIT

D*CG UNITS

 

180

975 / 2150

 

240

1066 / 2350

OPTIONS / ACCESSORIES

Economizer

 

73 / 160

Motorized Damper

68 / 150

 

 

18 kW

11 / 25

Electric

 

36 kW

14

/ 30

Heaters

 

54 kW

16

/ 35

 

 

72 kW

18

/ 40

Roof Curb

 

180

79 / 175

 

240

84 / 185

 

 

Barometric Damper

20

/ 45

Wood

 

180

91 / 200

Skid*

 

240

100

/ 220

*Allows handling of unit using 2300mm (90") long forks.

14

Unitary Products Group

Page 14
Image 14
York D3CE, D3CG manual Physical Data

D3CG, D3CE specifications

York D3CE and D3CG are innovative air-cooled chillers developed to address the growing demands for energy-efficient cooling solutions in commercial and industrial settings. These models are part of York's comprehensive range of HVAC products, showcasing advanced engineering and cutting-edge technologies designed to optimize performance while reducing operational costs.

One of the standout features of the York D3CE and D3CG series is their high efficiency. These chillers utilize a variable speed drive (VSD) technology that allows the compressor to adjust its speed according to the cooling load. This capability enhances energy efficiency, particularly in varying load conditions, and can lead to substantial energy savings compared to traditional fixed-speed chillers.

In terms of environmentally friendly refrigerants, both the D3CE and D3CG models are designed to operate with refrigerants that have low global warming potential (GWP). This aspect not only supports sustainability initiatives but also aligns with international regulations aimed at reducing greenhouse gas emissions. This makes them an appealing choice for organizations committed to minimizing their environmental impact.

The York D3CE and D3CG chillers are engineered to ensure quiet operation, making them suitable for noise-sensitive applications such as urban environments, hospitals, and educational institutions. Sound-dampening technologies are integrated into the design to minimize operational noise, thus preserving the quality of the surrounding environment.

Another significant characteristic is the advanced control system tailored for these chillers. The intuitive controls interface allows for easy monitoring and adjustment of operating parameters, enabling facilities managers to optimize performance and maintain effective cooling without extensive training.

Durability and reliability are also hallmarks of the D3CE and D3CG series. Constructed with high-quality materials and robust components, these models are engineered to withstand harsh operating conditions and deliver consistent performance over time. Regular maintenance can be managed efficiently thanks to accessible service points, ensuring that these chillers can serve their intended lifespan and beyond.

In summary, the York D3CE and D3CG series stands out in the crowded HVAC market due to their high efficiency, environmentally friendly design, quiet operation, advanced control capabilities, and rugged reliability. These features make them a prudent choice for organizations looking to enhance their cooling systems while adhering to environmental and economic sustainability goals.