York DM 072 warranty DM072 COOLING CAPACITIES 6 TON, Nominal Rating, 036-21502-003-A-1105

Models: DM 072

1 44
Download 44 pages 14.27 Kb
Page 19
Image 19
TABLE 8: DM072 COOLING CAPACITIES (6 TON)

036-21502-003-A-1105

TABLE 8: DM072 COOLING CAPACITIES (6 TON)

AIR ON

 

 

 

 

 

 

TEMPERATURE OF AIR ON CONDENSER COIL

 

 

 

 

 

 

 

 

 

 

 

85°F

 

 

 

 

 

 

 

 

 

95°F

 

 

 

 

 

EVAPORATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOTAL

 

 

SENSIBLE CAPACITY1

 

TOTAL

 

 

 

SENSIBLE CAPACITY1

 

 

COIL

POWER

 

 

POWER

 

 

 

 

 

 

1

 

ENTERING DRY BULB, °F

 

1

 

 

ENTERING DRY BULB, °F

 

 

 

 

CAP.

INPUT2 kW

 

 

CAP.

INPUT2 kW

 

 

 

CFM

 

WB °F

MBH

86

83

 

80

77

74

71

68

MBH

 

86

83

 

80

77

74

71

68

 

 

 

 

 

 

 

 

72

80

5.7

63

55

 

47

40

32

-

-

77

6.3

 

63

55

 

47

40

32

-

-

2700

 

67

80

5.7

76

68

 

60

53

45

37

30

77

6.3

 

75

68

 

60

53

45

37

30

 

62

70

5.5

70

70

 

70

62

55

47

39

71

6.3

 

71

71

 

71

63

56

48

40

 

 

 

 

 

 

 

57

68

5.6

68

68

 

68

60

52

45

37

71

6.3

 

71

71

 

71

63

56

48

40

 

 

72

82

5.7

60

53

 

46

38

31

-

-

76

6.3

 

60

53

 

46

39

31

-

-

2550

 

67

82

5.7

73

65

 

58

51

43

36

29

76

6.3

 

73

66

 

58

51

44

36

29

 

62

71

5.5

71

71

 

70

62

55

48

41

70

6.3

 

70

70

 

69

62

55

48

40

 

 

 

 

 

 

 

57

69

5.6

69

69

 

69

62

55

47

40

70

6.3

 

70

70

 

70

62

55

48

40

 

 

72

83

5.7

58

51

 

44

37

30

-

-

75

6.3

 

58

51

 

44

37

30

-

-

2400

 

67

83

5.7

70

63

 

56

49

42

35

28

75

6.3

 

70

64

 

57

50

43

36

29

 

62

73

5.5

73

73

 

70

63

56

49

42

69

6.3

 

69

69

 

68

61

54

47

40

 

 

 

 

 

 

 

57

71

5.6

71

71

 

71

64

57

50

43

69

6.3

 

69

69

 

68

61

54

47

40

 

 

72

79

5.7

54

48

 

41

35

29

-

-

73

6.3

 

53

47

 

41

35

29

-

-

2100

 

67

79

5.7

65

59

 

53

47

40

34

28

73

6.3

 

65

59

 

52

46

40

34

28

 

62

69

5.5

69

69

 

66

60

54

47

41

67

6.3

 

67

66

 

63

57

51

45

38

 

 

 

 

 

 

 

57

67

5.6

67

67

 

67

61

54

48

42

67

6.3

 

67

66

 

63

57

51

45

39

 

 

72

74

5.6

50

44

 

39

34

28

-

-

71

6.3

 

49

43

 

38

33

27

-

-

1800

 

67

74

5.6

60

55

 

50

44

39

34

28

71

6.3

 

59

54

 

48

43

38

32

27

 

62

65

5.4

65

65

 

62

57

51

46

41

65

6.2

 

65

63

 

58

53

47

42

37

 

 

 

 

 

 

 

57

63

5.5

63

63

 

63

58

52

47

42

65

6.3

 

65

63

 

58

53

47

42

37

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR ON

 

 

 

 

 

 

TEMPERATURE OF AIR ON CONDENSER COIL

 

 

 

 

 

 

 

 

 

 

 

105°F

 

 

 

 

 

 

 

 

 

115°F

 

 

 

 

 

EVAPORATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOTAL

 

 

SENSIBLE CAPACITY1

 

TOTAL

 

 

 

SENSIBLE CAPACITY1

 

 

COIL

POWER

 

 

POWER

 

 

 

 

 

 

1

 

ENTERING DRY BULB, °F

 

1

 

 

ENTERING DRY BULB, °F

 

 

 

 

CAP.

INPUT2 kW

 

 

CAP.

INPUT2 kW

 

 

 

CFM

 

WB °F

MBH

86

83

 

80

77

74

71

68

MBH

 

86

83

 

80

77

74

71

68

 

 

 

 

 

 

 

 

72

76

7.1

61

53

 

45

38

30

-

-

75

7.9

 

59

51

 

43

36

28

-

-

2700

 

67

71

7.1

70

66

 

58

50

43

35

27

65

7.8

 

65

64

 

56

48

41

33

25

 

62

64

7.0

64

64

 

64

56

49

41

34

57

7.8

 

57

57

 

57

50

42

34

27

 

 

 

 

 

 

 

57

64

7.0

64

64

 

64

56

49

41

34

57

7.7

 

57

57

 

57

50

42

34

27

 

 

72

76

7.1

59

51

 

44

37

29

-

-

76

7.9

 

57

49

 

42

35

27

-

-

2550

 

67

71

7.1

69

64

 

56

49

42

34

27

66

7.9

 

66

61

 

54

47

40

32

25

 

62

64

7.0

64

64

 

64

56

49

42

35

58

7.8

 

58

58

 

58

51

43

36

29

 

 

 

 

 

 

 

57

64

7.0

64

64

 

64

56

49

42

34

58

7.7

 

58

58

 

58

50

43

36

29

 

 

72

75

7.1

56

49

 

43

36

29

-

-

76

8.0

 

55

48

 

41

34

27

-

-

2400

 

67

70

7.1

68

61

 

54

48

41

34

27

66

7.9

 

66

59

 

52

45

38

32

25

 

62

64

7.0

64

64

 

63

56

49

42

35

59

7.8

 

59

59

 

59

52

45

38

31

 

 

 

 

 

 

 

57

64

7.0

64

64

 

63

56

49

42

35

59

7.7

 

59

59

 

58

51

44

37

30

 

 

72

73

7.1

52

45

 

39

33

27

-

-

73

7.9

 

50

44

 

37

31

25

-

-

2100

 

67

68

7.1

63

56

 

50

44

38

32

26

63

7.8

 

61

54

 

48

42

36

30

24

 

62

61

7.0

61

61

 

58

52

46

40

34

56

7.7

 

56

56

 

54

48

42

35

29

 

 

 

 

 

 

 

57

61

7.0

61

61

 

58

52

46

40

34

56

7.7

 

56

56

 

53

47

41

35

29

 

 

72

70

7.1

47

41

 

36

31

25

-

-

69

7.8

 

45

40

 

34

29

23

-

-

1800

 

67

65

7.0

57

51

 

46

41

35

30

25

60

7.8

 

55

49

 

44

39

33

28

23

 

62

59

7.0

59

58

 

54

48

43

38

32

53

7.7

 

53

53

 

49

44

39

33

28

 

 

 

 

 

 

 

57

59

6.9

59

58

 

53

48

43

37

32

53

7.6

 

53

53

 

49

44

38

33

27

1.These capacities are gross ratings. For net capacity, determine the kW of the supply air blower motor from the SUPPLY AIR BLOWER PERFORMANCE Table, multiply this value by 3.415 MBH/kW to determine the motor heat, and deduct this heat from the gross capacity of the unit.

2.These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input

is 0.36kW. Refer to the SUPPLY AIR BLOWER PERFORMANCE Table for the kW of the supply air blower motor.

Manual background NOMINAL RATING

Unitary Products Group

19

Page 19
Image 19
York DM 072 warranty DM072 COOLING CAPACITIES 6 TON, Nominal Rating, 036-21502-003-A-1105, Unitary Products Group