TYPICAL POWER WIRING
|
| REFER TO THE ELECTRICAL DATA |
|
|
|
|
|
| TABLES TO SIZE THE DISCONNECT |
|
|
|
|
|
| SWITCH, OVERCURRENT PROTEC- |
|
|
|
|
|
| TION AND WIRING. |
|
|
|
|
|
| TYPICAL CONTROL WIRING |
|
| ||
COOLING ONLY (24 VOLT THERMOSTAT) | COOLING / HEATING (24 VOLT THERMOSTAT) | |||||
|
|
|
| |||
|
|
| THERMOSTAT1 |
|
| |
THERMOSTAT1 | UNIT TERMINAL |
| TERMINALS |
|
| |
TERMINALS | STRIP TB1 |
|
| RH | UNIT TERMINAL |
|
|
|
|
| STRIP TB1 |
| |
|
|
| ADD |
|
| |
RV | R |
|
|
|
| |
| JUMPER | RC | R |
| ||
|
|
|
| |||
YC | Y1 | 24 VOLT |
| Y | Y1 |
|
TRANSFORMER |
| 24 VOLT | ||||
|
|
|
|
| TRANSFORMER | |
|
|
|
|
|
| |
|
|
|
|
| Y2 |
|
| Y2 |
|
|
|
|
|
|
|
|
| W | W1 |
|
GF | G |
|
|
| W2 |
|
|
|
|
|
|
| |
| C |
|
| G | G |
|
|
|
|
|
| C |
|
124 VOLT THERMOSTAT 2TH07701024. TO CONTROL THE ECONOMIZER |
|
|
|
| ||
ON SECOND STAGE COOLING, USE THE THERMOSTAT 2TH0401224. | 124 VOLT THERMOSTAT 2ET07701024. TO CONTROL THE ECONOMIZER ON THE SECOND | |||||
|
|
| ||||
|
|
| STAGE COOLING OR TO HAVE AN ELECTRIC HEAT ACCESSORY WITH TWO STAGES OF | |||
|
|
| HEAT, USE THERMOSTAT 2TH0471024. |
|
COOLING / HEATING (ELECTRONIC THERMOSTAT) | COOLING / HEATING (ELECTRONIC THERMOSTAT) | |||||||
|
| MULTI STAGE |
|
|
| SINGLE STAGE | ||
|
|
|
|
|
|
|
| |
| THERMOSTAT1 |
|
|
|
|
|
| |
| TERMINALS |
| UNIT TERMINAL |
|
| THERMOSTAT1 |
| |
ADD |
| RC |
| STRIP TB1 | 24 VOLT |
|
| |
| RH |
| R | TRANSFORMER |
| TERMINALS | UNIT TERMINAL | |
JUMPER |
|
|
| |||||
|
|
|
|
|
|
| STRIP TB1 | |
|
| Y1 |
| Y1 |
|
| RH | |
|
| Y2 | 2 | Y2 |
|
|
| |
|
|
|
|
|
| |||
|
| W1 |
| W1 |
|
| RC | R |
| 4 | W2 | 3 | W2 |
| ADD | Y | Y1 |
|
|
| ||||||
|
| G |
| G |
| JUMPER | ||
|
|
|
|
|
| |||
|
| B |
| C |
|
| W | W1 |
|
| LED 1 |
| X |
|
| G | G |
|
| LED 2 NOT |
|
|
|
| ||
|
|
| OCC |
|
|
| C | |
|
| USED | 4 |
|
|
|
| |
ADD |
| COM |
|
|
|
| 24 VOLT | |
| A1 |
|
|
|
|
| ||
JUMPER |
| A2 |
|
|
|
|
| TRANSFORMER |
|
| T | TO REMOTE SENSOR |
|
|
| ||
|
|
|
|
|
| |||
|
| T | 2TH040702224 IF USED |
|
|
|
1ELECTRONIC PROGRAMMABLE THERMOSTAT 2ET04700224 (INCLUDES SUBBASE).
2SECOND STAGE COOLING IS NOT REQUIRED ON UNITS LESS ECONOMIZER.
3SECOND STAGE HEATING IS ONLY REQUIRED ON UNITS WITH A TWO STAGE ELECTRIC HEATER OR 2 STAGE GAS HEAT.
4REMOVE JUMPER J2 FROM TERMINALS 4 AND 9 ON JUMPER PLUG CONNECTOR P6 ON UNITS WITH ECONOMIZER. TERMINALS A1 AND A2 PROVIDE A RELAY
1ELECTRONIC PROGRAMMABLE THERMOSTAT 2ET07701024 (INCLUDES SUBBASE).
TO CONTROL THE ECONOMIZER ON SECOND STAGE COOLING, USE THERMOSTAT 2TH04700224.
FIGURE 2 - TYPICAL FIELD POWER & CONTROL WIRING
Unitary Products Group | 35 |