HAIL GUARD KIT - Kit contains protective grilles made of expanded aluminum with full perimeter frame. Sloped hoods are also included to assure maximum protection.
ANTI SHORT CYCLE TIMER - Automatically prevents the compressor from restarting for 5 minutes after cycled off.Not required if Thermostat 2ET07700224 and 2ET04700224 are used.
FILTER / FRAME KIT (Single Phase only) - Kit contains the necessary hardware to field install return air filters into the base unit.
MOTORIZED FRESH AIR DAMPER - Designed for duct mounted side supply/return and unit mounted down supply/ return applications. Damper capable of providing 0% through 50% of outdoor air (field supplied). Closes on power loss, includes hood and screen assembly.
openings on the base unit. Transition is from side square duct opening to 14" round duct opening.
ROOF CURBS - NRCA approved curbs provide proper fit to base unit for rooftop installations. Curbs are designed to be assembled through hinge pins in each corner. Kit also pro- vides seal strip to assure a water tight seal. 8 and 14 inch high roof curbs are available.
MANUAL OUTDOOR DAMPER - Provides 0% through 50% outdoor air capability (field adjustable). Designed for duct mounted side supply/return applications. Includes hood and screen assembly.
WALL THERMOSTAT - The units are designed to operate with
LOW AMBIENT KIT - Kit provides necessary hardware to convert unit to operate in cooling cycle down to 0 F. Standard unit operation 45 F.
RECTANGLE TO ROUND ADAPTERS - Kit includes one |
| TRANSFORMER KIT - Kit provides necessary hardware to pro- | |||||||
| vide single phase models from factory furnished 40 VA trans- | ||||||||
supply and one return air rectangle to round duct adapter. |
| ||||||||
| former capability to 75 VA transformer capability. (Required on | ||||||||
Adapters are preformed and designed to fit over current duct |
| ||||||||
| installations with economizer or motorized damper.) | ||||||||
|
|
|
| ||||||
|
|
|
|
|
|
| DIRECT |
| IVE |
|
|
|
| CONDENSE | FAN | ||||
|
|
|
| MOTOR |
| ||||
STEELTUBULARHEAT |
|
|
|
|
|
|
| ||
WITHRIABLELUMINIZED |
|
|
|
|
|
|
| ||
EXCHANGERS |
|
| HIGHLYENHNCEREFFICIE |
|
| ||||
|
|
|
|
| COPPERTUBE/ALUMINUMFIN | ||||
|
|
|
|
|
| EVAPORATORHIGHLYCOILEFFICIENT | |||
|
|
|
|
| ENHANCEDCOPPER | ||||
|
|
|
|
| TUBE/ALUMINUMFIN | ||||
PWDEROFINISHPAINT |
|
|
|
|
| CONDENSERDECORATIVECOIL | |||
|
|
|
|
|
|
|
| PROTECTIVE | |
REAR&BOTTOM |
|
|
|
|
| COILGUARD | |||
|
|
|
|
| HIGHEFFICIENCY | ||||
RETRNAIR |
|
|
|
|
| ||||
|
|
|
|
|
|
| COMPRESSOR | ||
ANDSUPLYAIR |
|
|
|
|
| RIGIDLYMOUNTED | |||
DUCTOENINGSP |
|
|
|
|
| H | SURFACE | ||
HAVYGUGE |
|
|
|
|
|
| PILOTASSEMBLY | ||
RMOVEABLE |
|
|
|
|
| HIGHGRADE | |||
BASERAILS |
|
|
|
|
|
|
| ||
|
|
|
|
| ALUMINIZED | ||||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| TERMINALBLOCK | ||
|
|
|
| LOWVOLTAGE | |||||
|
| ||||||||
BLOWERMOTORWITH |
|
| |||||||
BLOWERASSEMBLY |
|
| AUTOWITHMATIC"COMFORTCONTROLMATCH"SPEED | ||||||
|
| POWERVENTERMOTOR | HIGHVOLTAGE | GASVALVE |
|
|
| ||
|
|
|
|
|
|
| |||
|
|
| TERMINALBLOCK |
|
|
|
|
|
FIGURE 1 - UNIT COMPONENT LOCATION
Unitary Products Group | 5 |