FIGURE 4 - UNIT DIMENSIONS - FRONT
TABLE 17: UNIT DIMENSIONS FRONT
UNIT SIZE |
| DIMENSION | |
“A” |
| “B” | |
|
| ||
018 - 036 |
| ||
042 - 060 |
|
TABLE 18: UNIT MINIMUM CLEARANCES1 2
CLEARANCES
FRONT | 36” |
REAR | 0” |
LEFT SIDE | 24” |
RIGHT SIDE | 12” |
BELOW UNIT3 | 0” |
ABOVE UNIT 4 | 36” (For Condenser Air Discharge |
1.A 1” clearance must be provided between any combus- tible material and the supply air ductwork.
2.The products of combustion must not be allowed to accumulate within a confined space and recirculate.
3.Units may be installed on combustible floors made from wood or class A, B, or C roof covering material.
4.Units must be installed outdoors. Overhanging struc- tures or shrubs should not obstruct condenser air dis- charge outlet.
Unitary Products Group | 21 |