York GNA, GHA, GFD, GHD, GUA, GFA specifications COOLING CAPACITY - Coil Only, 036-21145-003Rev. A

Models: GFA GUA GHD GNA GFD GHA

1 12
Download 12 pages 21.54 Kb
Page 2
Image 2

036-21145-003 Rev. A (0403)

COOLING CAPACITY - Coil Only*

 

RATED

ENTERING

MBH @ EVAPORATOR TEMPERATURE AND CORRESPONDING

MODEL

AIR ° F

 

 

PRESSURE °F / PSIG

 

 

CFM

(WET BULB)

 

 

 

 

 

 

35 / 61.5

 

40 / 68.5

45 / 76.0

50 / 84.0

 

 

 

 

 

 

UPFLOW "A" TYPE

 

 

 

 

 

 

72

35.6

 

32.5

29.0

25.2

G1FA024S14(T)

675

67

32.9

 

29.7

26.3

22.7

G1UA024S14

 

 

 

 

 

 

62

27.0

 

23.9

20.7

17.4

 

 

 

 

57

21.9

 

19.0

15.9

12.4

 

 

72

35.6

 

32.5

29.0

25.2

G1FA024S17(T)

850

67

32.9

 

29.7

26.3

22.7

G1UA024S17

 

 

 

 

 

 

62

27.0

 

23.9

20.7

17.4

 

 

 

 

57

21.9

 

19.0

15.9

12.4

 

 

72

38.9

 

35.4

31.6

27.6

G1FA030S14(T)

1025

67

33.9

 

30.3

26.8

23.0

G1UA030S14

 

 

 

 

 

 

62

27.3

 

23.7

22.5

18.0

 

 

 

 

57

22.6

 

20.1

17.5

14.8

G1FA036S14(T)

 

72

51.1

 

46.5

41.5

36.6

G1FA036S17(T)

1250

67

40.9

 

36.1

31.7

26.9

G1UA036S14

 

 

 

 

 

 

62

32.0

 

26.8

29.3

21.8

 

 

G1UA036S17

 

 

 

 

 

 

 

 

57

27.4

 

25.4

23.4

21.8

 

 

72

51.1

 

46.5

41.5

36.6

G1FA036S21(T)

1250

67

40.9

 

36.1

31.7

26.9

G1UA036S21

 

 

 

 

 

 

62

32.0

 

26.8

29.3

21.8

 

 

 

 

57

27.4

 

25.4

23.4

21.8

G1FA048S17(T)

 

72

99.4

 

85.5

71.2

56.2

G1FA048S21(T)

1620

67

79.6

 

66.8

54.4

41.6

G1UA048S17

 

 

 

 

 

 

62

62.1

 

49.4

40.2

33.7

 

 

G1FUA048S21

 

 

 

 

 

 

 

 

57

53.3

 

46.7

40.2

33.7

G1FA060S21(T)

 

72

118.7

 

100.0

81.1

61.5

G1FA060S24(T)

1850

67

95.0

 

78.4

61.9

45.4

G1UA060S21

 

 

 

 

 

 

62

74.0

 

58.0

45.7

36.7

 

 

G1UA060S24

 

 

 

 

 

 

 

 

57

63.6

 

54.8

45.7

36.7

*- See Condensing Unit or Heat Pump Technical Guide for Total Cooling Capacity and Sensible Capacity.

(T) indicates models with factory installed thermal expansion valve.

Coil Only*

MODEL

RATED

ENTERING

MBH @ EVAPORATOR TEMPERATURE AND CORRESPONDING PRESSURE

AIR ° F

 

 

 

°F/ PSIG

 

 

CFM

(WET BULB)

 

 

 

 

 

 

 

35 / 61.5

 

40 / 68.5

 

45 / 76.0

50 / 84.0

 

 

 

 

 

 

HORIZONTAL DUCT TYPE

 

 

 

 

 

 

72

35.3

 

32.4

 

28.7

24.9

G1HD024

815

67

32.6

 

29.4

 

26.0

22.5

62

26.7

 

23.7

 

20.5

17.2

 

 

 

 

 

 

57

21.7

 

18.8

 

15.7

12.3

 

 

72

57.9

 

52.7

 

47.1

41.5

G1HD036

1192

67

46.4

 

41.1

 

35.9

30.4

62

36.2

 

30.4

 

26.5

24.7

 

 

 

 

 

 

57

31.1

 

28.7

 

26.5

24.7

 

 

72

83.4

 

71.7

 

59.7

47.1

G1HD048

1610

67

66.8

 

56.1

 

45.6

34.9

62

52.1

 

41.5

 

33.7

28.3

 

 

 

 

 

 

57

44.7

 

39.2

 

33.7

28.3

 

 

72

133.0

 

112.4

 

90.9

69.2

G1HD060

2100

67

106.5

 

87.9

 

69.4

50.0

62

83.0

 

65.0

 

51.3

41.1

 

 

 

 

 

 

57

71.2

 

61.4

 

51.3

41.1

*See Condensing Unit or Heat Pump Technical Guide for Total Cooling Capacity and Sensible Capacity.

2

Unitary Products Group

Page 2
Image 2
York GNA, GHA, GFD, GHD, GUA, GFA specifications COOLING CAPACITY - Coil Only, 036-21145-003Rev. A