York GUA, GHA, GFD, GNA, GHD Application Factor-Rated Cfm Vs. Actual Cfm, Application Limitations

Models: GFA GUA GHD GNA GFD GHA

1 12
Download 12 pages 21.54 Kb
Page 4
Image 4
APPLICATION FACTOR-RATED

036-21145-003 Rev. A (0403)

COOLING CAPACITY - COIL ONLY*

MODEL COIL

RATED CFM

ENTERING AIR °F (WET BULB)

MBH@ EVAPORATOR TEMPERATURE AND CORRESPONDING PRESSURE °F / PSIG

35 / 61.5

40 / 68.5

45 / 76.0

50 / 84.0

 

 

 

 

 

 

UNCASED UPFLOW

 

 

 

 

 

72

27.4

25.0

22.3

19.4

G1NA024S17G

800

67

25.3

22.9

20.3

17.5

62

20.8

18.4

15.9

13.4

 

 

 

 

57

16.9

14.6

12.2

9.4

 

 

72

35.2

32.0

28.6

24.8

G1NA030S17H

1000

67

32.4

28.6

25.3

21.9

62

26.6

23.6

21.5

18.7

 

 

 

 

57

25.2

22.7

20.2

17.6

 

 

72

39.6

36.0

32.1

27.9

G1NA030S17K

1000

67

36.4

33.2

29.5

25.7

62

29.9

27.2

24.2

21.0

 

 

 

 

57

28.1

25.6

22.7

19.8

 

 

72

49.3

44.9

39.9

34.7

G1NA036S17J

1200

67

45.4

41.3

36.7

32.0

62

37.2

33.8

30.1

26.2

 

 

 

 

57

35.0

28.3

28.3

24.6

 

 

72

59.9

54.5

48.5

42.6

G1NA036S17L

1200

67

55.1

51.1

44.6

38.9

62

45.2

41.1

36.6

31.9

 

 

 

 

57

42.5

38.7

34.4

30.0

 

 

72

49.3

44.9

39.9

34.7

G1NA036S21C

1200

67

45.4

41.3

36.7

32.0

62

37.2

33.8

30.1

26.2

 

 

 

 

57

35.0

31.8

28.3

24.6

 

 

72

86.7

73.0

59.2

44.9

G1NA042S24W

1400

67

69.4

57.2

45.2

33.1

62

54.0

42.3

33.4

26.8

 

 

 

 

57

46.4

40.0

33.4

26.8

 

 

72

62.4

56.8

50.5

44.4

G1NA048S21D

1400

67

57.4

53.2

46.5

40.5

62

47.1

42.8

38.1

33.2

 

 

 

 

57

44.3

40.3

35.8

31.2

 

 

72

95.4

82.1

68.4

54.0

G1NA060S24T

1800

67

76.4

64.1

52.2

39.9

62

59.6

47.4

38.6

32.4

 

 

 

 

57

51.2

44.8

38.6

32.4

*See Condensing Unit or Heat Pump Technical Guide for Total Cooling Capacity and Sensible Capacity.

APPLICATION FACTOR-RATED

CFM VS. ACTUAL CFM

% OF RATED AIR FLOW

80%

90%

RATED CFM

110%

120%

 

 

 

 

 

 

CAPACITY FACTOR

0.96

0.98

1.00

1.02

1.03

 

 

 

 

 

 

NOTE: Do not exceed minimum/maximum CFM limits shown under Air Flow Data.

APPLICATION LIMITATIONS

These units must be installed in accordance with all national and local safety codes.

Air flow must be within the minimum and maximum limits approved for electric heat, evaporator coils and outdoor units.

ENTERING AIR TEMPERATURE LIMITS

WET BULB TEMP. ºF

DRY BULB TEMP. ºF

Min.

Max.

Min.

Max.

57

72

65

95

4

Unitary Products Group

Page 4
Image 4