HIGH ALTITUDE PRESSURE SWITCH APPLICATION

036-21560-001 Rev. A (0204)

HIGH ALTITUDE PRESSURE SWITCH APPLICATION

Input (MBH)

Output (MBH)

4,500 To 10,000 Ft.

Upflow Models

 

 

 

 

 

60/1200

55

1PS0901

80/1200

74

1PS0902

80/1600

74

1PS0903

100/1600

93

1PS0901

100/2000

93

1PS0901

120/2000

112

1PS0901

NOTE: For high altitude conversion, an orifice change may also be required. See Form 035-14460-001 for application information.

ELECTRICAL AND PERFORMANCE DATA

 

Input

Output

 

Nominal Airflow

Cabinet Width

AFUE

Air Temp. Rise

MBH

 

kW

MBH

 

kW

CFM

m3/min

In.

mm

%

°F

°C

60

 

18

55

 

16.1

1200

34.0

17-1/2

444

91

40 - 70

22 - 39

80

 

23

74

 

21.7

1200

34.0

17-1/2

444

91

35 - 65

19 - 36

80

 

23

74

 

21.7

1600

45.3

21

533

91

40 - 70

22 - 39

100

 

29

93

 

27.3

1600

45.3

21

533

91

35 - 65

19 - 36

100

 

29

93

 

27.3

2000

56.6

21

533

91

35 - 65

19 - 36

120

 

35

112

 

32.8

2000

56.6

24-1/2

622

91

35 - 65

19 - 36

 

 

 

 

 

 

 

 

 

 

 

 

 

Input

Max. Outlet

Blower

Blower Size

Total Unit

Max.

Min. Wire Size

 

Air Temp.

Over-current

(awg) @ 75 ft.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Protect

One Way

MBH

 

kW

°F

 

°C

HP

Amps

In.

mm

Amps

60

 

18

170

 

76.7

1/2

7.0

11 x 8

279 x 203

9

20

14

80

 

23

170

 

76.7

1/2

7.0

11 x 8

279 x 203

9

20

14

80

 

23

170

 

76.7

3/4

10.2

11 x 10

279 x 254

12

20

14

100

 

29

175

 

79.4

3/4

10.2

11 x 10

254 x 254

12

20

14

100

 

29

175

 

79.4

1

12.7

11 x 11

279 x 279

14

20

12

120

 

35

175

 

76.7

1

12.7

11 x 11

279 x 279

14

20

12

*Wire size and overcurrent protection must comply with the National Electric Code.

NOTES:

1.For altitudes above 2000 ft. reduce capacity 4% for each 1000 ft. above sea level.

2.Wire size based on copper conductors, 60°C, 3% voltage drop.

3.Continuous return air temperature must not be below 55°F.

MODEL

FILTER SIZE

ADD-ON COOLING

APPROX.

NUMBER

TONS

CFM* @ .5 ESP

OPER. WEIGHT

 

 

 

 

 

 

GY9S060B12DH11

 

1-1/2, 2, 2-1/2, 3

1550

130

GY9S080B12DH11

 

2, 2-1/2, 3

1530

145

GY9S080C16DH11

(2) 14 x 20

3, 3-1/2, 4

1860

155

GY9S100C16DH11

3, 3-1/2, 4

1830

170

 

GY9S100C20DH11

 

3-1/2, 4, 5

2000

175

GY9S120D20DH11

 

3-1/2, 4, 5

2100

180

*ESP (External Static Pressure) .5" WG is at furnace outlet ahead of cooling coil.

NOTES:

1. All filters must be high velocity cleanable type.

FIELD WIRING DIAGRAMS

BLK

BLK (HOT)

 

 

 

NOMINAL

WHT

WHT (NEUTRAL)

115 VOLT

GRN

GRD

 

POWER WIRING

ROOM

FURNACE

CONDENSING

THERMOSTAT

CONTROL

UNIT

R

R

 

W

W

TO AIR CONDITIONER

G

G

CONTROLS

 

Y

Y

 

C

C

 

Unitary Products Group