HIGH ALTITUDE PRESSURE SWITCH APPLICATION
Input (MBH) | Output (MBH) | 4,500 To 10,000 Ft. | |
Upflow Models | |||
|
| ||
|
|
| |
60/1200 | 55 | 1PS0901 | |
80/1200 | 74 | 1PS0902 | |
80/1600 | 74 | 1PS0903 | |
100/1600 | 93 | 1PS0901 | |
100/2000 | 93 | 1PS0901 | |
120/2000 | 112 | 1PS0901 |
NOTE: For high altitude conversion, an orifice change may also be required. See Form
ELECTRICAL AND PERFORMANCE DATA
| Input | Output |
| Nominal Airflow | Cabinet Width | AFUE | Air Temp. Rise | |||||
MBH |
| kW | MBH |
| kW | CFM | m3/min | In. | mm | % | °F | °C |
60 |
| 18 | 55 |
| 16.1 | 1200 | 34.0 | 444 | 91 | 40 - 70 | 22 - 39 | |
80 |
| 23 | 74 |
| 21.7 | 1200 | 34.0 | 444 | 91 | 35 - 65 | 19 - 36 | |
80 |
| 23 | 74 |
| 21.7 | 1600 | 45.3 | 21 | 533 | 91 | 40 - 70 | 22 - 39 |
100 |
| 29 | 93 |
| 27.3 | 1600 | 45.3 | 21 | 533 | 91 | 35 - 65 | 19 - 36 |
100 |
| 29 | 93 |
| 27.3 | 2000 | 56.6 | 21 | 533 | 91 | 35 - 65 | 19 - 36 |
120 |
| 35 | 112 |
| 32.8 | 2000 | 56.6 | 622 | 91 | 35 - 65 | 19 - 36 | |
|
|
|
|
|
|
|
|
|
|
|
| |
| Input | Max. Outlet | Blower | Blower Size | Total Unit | Max. | Min. Wire Size | |||||
| Air Temp. | (awg) @ 75 ft. | ||||||||||
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
| Protect | One Way |
MBH |
| kW | °F |
| °C | HP | Amps | In. | mm | Amps | ||
60 |
| 18 | 170 |
| 76.7 | 1/2 | 7.0 | 11 x 8 | 279 x 203 | 9 | 20 | 14 |
80 |
| 23 | 170 |
| 76.7 | 1/2 | 7.0 | 11 x 8 | 279 x 203 | 9 | 20 | 14 |
80 |
| 23 | 170 |
| 76.7 | 3/4 | 10.2 | 11 x 10 | 279 x 254 | 12 | 20 | 14 |
100 |
| 29 | 175 |
| 79.4 | 3/4 | 10.2 | 11 x 10 | 254 x 254 | 12 | 20 | 14 |
100 |
| 29 | 175 |
| 79.4 | 1 | 12.7 | 11 x 11 | 279 x 279 | 14 | 20 | 12 |
120 |
| 35 | 175 |
| 76.7 | 1 | 12.7 | 11 x 11 | 279 x 279 | 14 | 20 | 12 |
*Wire size and overcurrent protection must comply with the National Electric Code.
NOTES:
1.For altitudes above 2000 ft. reduce capacity 4% for each 1000 ft. above sea level.
2.Wire size based on copper conductors, 60°C, 3% voltage drop.
3.Continuous return air temperature must not be below 55°F.
MODEL | FILTER SIZE | APPROX. | |||
NUMBER | TONS | CFM* @ .5 ESP | OPER. WEIGHT | ||
| |||||
|
|
|
|
| |
GY9S060B12DH11 |
| 1550 | 130 | ||
GY9S080B12DH11 |
| 2, | 1530 | 145 | |
GY9S080C16DH11 | (2) 14 x 20 | 3, | 1860 | 155 | |
GY9S100C16DH11 | 3, | 1830 | 170 | ||
| |||||
GY9S100C20DH11 |
| 2000 | 175 | ||
GY9S120D20DH11 |
| 2100 | 180 |
*ESP (External Static Pressure) .5" WG is at furnace outlet ahead of cooling coil.
NOTES:
1. All filters must be high velocity cleanable type.
FIELD WIRING DIAGRAMS
BLK | BLK (HOT) |
|
|
| NOMINAL |
WHT | WHT (NEUTRAL) | 115 VOLT |
GRN | GRD |
|
POWER WIRING
ROOM | FURNACE | CONDENSING |
THERMOSTAT | CONTROL | UNIT |
R | R |
|
W | W | TO AIR CONDITIONER |
G | G | CONTROLS |
| ||
Y | Y |
|
C | C |
|
Unitary Products Group | 3 |