York LY8S*UH, GY8S*UH warranty Horizontal Sidewall Venting, Filter Performance

Models: GY8S*UH LY8S*UH

1 8
Download 8 pages 17.7 Kb
Page 6
Image 6

278436-YTG-A-0407

HORIZONTAL SIDEWALL VENTING

For applications where vertical venting is not possible, the only approved method of horizontal venting is the use of an auxiliary power vent. Approved power venters are Fields Controls Model SWG-4Y or Tjernlund Model GPAK-JT. Fol- low all application and installation details provided by the manufacturer of the power vent. This unit may be horizontally vented using 4” (10.2 cm) diameter pipe with a minimum length of 4.5 feet (1.37 m) and a maximum length of 34.5 feet (10.82 m) with up to 4 elbows.

FILTER PERFORMANCE

The airflow capacity data published in the “Blower Perfor- mance” table listed above represents blower performance WITHOUT filters. To determine the approximate blower per- formance of the system, apply the filter drop value for the fil- ter being used or select an appropriate value from the “Filter Performance” table shown below.

NOTE: The filter pressure drop values in the “Filter Perfor- mance” table shown below are typical values for the type of filter listed and should only be used as a guideline. Actual pressure drop ratings for each filter type vary between filter manufacturer.

RECOMMENDED FILTER SIZES

CFM

Cabinet

Side

Bottom

Size

(in)

(in)

 

 

 

 

 

1200

A

16 x 25

14 x 25

1200

B

16 x 25

16 x 25

1600

B

16 x 25

16 x 25

1600

C

16 x 25

20 x 25

2000

C

(2) 16 x 25

20 x 25

2200

C

(2) 16 x 25

20 x 25

2000

D

(2) 16 x 25

22 x 25

NOTES:

1.Air velocity through throwaway type filters may not exceed 300 feet per minute. All velocities over this require the use of high velocity filters.

2.Air flows above 1800 CFM require either return from two sides or one side plus bottom.

FILTER PERFORMANCE - PRESSURE DROP INCHES W.C. AND (KPA)

Airflow Range

Minimum

 

Filter Type

 

Opening Size

Disposable

Washable Fiber

Pleated

 

 

 

 

 

 

CFM

in2

In W.C.

In W.C.

In W.C.

0 - 750

230

0.01

0.01

0.15

 

 

 

 

 

751 - 1000

330

0.05

0.05

0.20

 

 

 

 

 

1001 - 1250

330

0.10

0.10

0.20

 

 

 

 

 

1251 - 1500

330

0.10

0.10

0.25

 

 

 

 

 

1501 - 1750

380

0.15

0.14

0.30

 

 

 

 

 

1751 - 2000

380

0.19

0.18

0.30

 

 

 

 

 

2001 & Above

463

0.19

0.18

0.30

 

 

 

 

 

UNIT CLEARANCES TO COMBUSTIBLES (ALL DIMENSIONS IN INCHES, AND ALL SURFACES IDENTIFIED WITH THE UNIT IN AN UPFLOW CONFIGURATION)

Application

Top

Front

Rear

Left

Right

Flue

Floor/

Closet

Alcove

Attic

Line

Side

Side

Bottom

Contact

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Upflow

1

6

0

0

3

6

Combustible

Yes

Yes

Yes

No

Upflow B-Vent

1

3

0

0

0

1

Combustible

Yes

Yes

Yes

No

Horizontal

1

6

0

0

3

6

Combustible

No

Yes

Yes

Yes1

Horizontal B-Vent

1

3

0

0

0

1

Combustible

No

Yes

Yes

Yes1

1.Line contact only permitted between lines formed by the intersection of the rear panel and side panel (top in horizontal postion) of the furance jacket and building joists, studs or framing.

6

Unitary Products Group

Page 6
Image 6
York LY8S*UH, GY8S*UH warranty Horizontal Sidewall Venting, Filter Performance