HIGH ALTITUDE PRESSURE SWITCH APPLICATION
Models |
|
| High Altitude Pressure Switch Kit |
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| 4,500 Ft to 10,000 Ft. |
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PV9A12N040UP11 |
|
|
|
| 1PS0506 |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PV9B12N060UP11 |
|
|
|
| 1PS0501 |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PV9B12N080UP11 |
|
|
|
| 1PS0502 |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PV9C16N080UP11 |
|
|
|
| 1PS0503 |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PV9C20N100UP11 |
|
|
|
| 1PS0505 |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PV9D20N120UP11 |
|
|
|
| 1PS0503 |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTE: For high altitude conversion, an orifice change may also be required. See Form |
| |||||||||||||||||
ELECTRICAL AND PERFORMANCE DATA |
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Input |
| Output | Nominal | AFUE | Air Temp. | Max. Outlet |
| Blower | Blower | Total Unit |
| Max. | Min. Wire Size | |||
Models | High/Low | High/Low | Airflow | Rise | Air Temp. |
| Size | (awg) @ 75 ft. | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Protect | One Way |
|
| MBH |
| MBH | CFM | % | °F | °F |
| HP | Amps | In. | Amps | |||||
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PV9A12N040UP11 |
| 40/26 | 38/24 | 1200 | 94.0 | 165 |
|
| 1/2 | 7.7 | 11x8 | 9 | 20 | 14 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PV9B12N060UP11 |
| 60/39 | 56/36 | 1200 | 93.2 | 170 |
|
| 1/2 | 7.7 | 11x8 | 9 | 20 | 14 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PV9B12N080UP11 |
| 80/52 | 75/49 | 1200 | 92.5 | 175 |
|
| 1/2 | 7.7 | 11x8 | 9 | 20 | 14 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PV9C16N080UP11 |
| 80/52 | 75/49 | 1600 | 92.8 | 175 |
|
| 3/4 | 9.6 | 11x10 | 12 | 20 | 14 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PV9C20N100UP11 |
| 100/65 | 93/60 | 2000 | 92.8 | 175 |
|
| 1 | 12.8 | 11x11 | 14 | 20 | 12 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PV9D20N120UP11 |
| 120/78 | 112/73 | 2000 | 93.2 | 170 |
|
| 1 | 12.8 | 11x11 | 14 | 20 | 12 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures. |
|
|
|
| ||||||||||||||
Wire size and over current protection must comply with the National Electrical Code |
| |||||||||||||||||
The furnace shall be installed so that the electrical components are protected from water. |
|
|
|
|
|
| ||||||||||||
FILTER SIZES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
Models |
| CFM |
| Cabinet Size | Side Return Filter in. (cm) |
| Bottom Return Filter in. (cm) |
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
PV9A12N040UP11 | 1200 |
| A |
|
|
| 16 x 25 |
|
|
|
|
| 14 x 25 |
|
|
|
| |
PV9B12N060UP11 | 1200 |
| B |
|
|
| 16 x 25 |
|
|
|
|
| 16 x 25 |
|
|
|
| |
PV9B12N080UP11 | 1200 |
| B |
|
|
| 16 x 25 |
|
|
|
|
| 16 x 25 |
|
|
|
| |
PV9C16N080UP11 | 1600 |
| C |
|
|
| 16 x 25 |
|
|
|
|
| 20 x 25 |
|
|
|
| |
PV9C20N100UP11 | 2000 |
| C |
|
|
| 16 x 25 |
|
|
|
|
| 20 x 25 |
|
|
|
| |
PV9D20N120UP11 | 2000 |
| D |
|
|
| (2) 16 x 25 |
|
|
|
|
| 22 x 25 |
|
|
|
|
*ESP (External Static Pressure) .5" WG is at furnace outlet ahead of cooling coil.
NOTES:
1.All filters must be high velocity cleanable type.
2.Air flows above 1800 CFM require either return from two sides or one side plus bottom.
Unitary Products Group | 3 |