York PV9 warranty Filter Performance

Models: PV9

1 8
Download 8 pages 30.04 Kb
Page 5
Image 5
FILTER PERFORMANCE

036-21584-001 Rev. B (1004)

BLK

BLK (HOT)

NOMINAL

WHT

WHT (NEUTRAL)

120 VOLT

 

 

GRN

GRN

 

LINE WIRING CONNECTIONS

ROOM

FURNACE

 

CONDENSING

THERMOSTAT

CONTROL

 

UNIT

 

R

 

 

 

 

 

R

 

TO AIR CONDITIONER

 

 

 

 

 

W1

 

W1/W

 

CONTROLS

 

W2

 

 

 

 

 

W2

 

 

 

 

 

 

 

 

 

 

 

 

G

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y1

 

 

 

 

 

Y1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y2

 

 

Y/Y2

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

C

 

 

 

COMMON T’STAT CONNECTION

TWO-STAGE HEATING AND TWO-STAGE COOLING

THERMOSTAT CONNECTIONS

ROOM

 

FURNACE

 

CONDENSING

THERMOSTAT

 

CONTROL

 

UNIT

 

R

 

 

 

R

 

TO AIR CONDITIONER

 

 

 

 

W

 

 

 

 

 

 

W1/W

 

CONTROLS

 

G

 

 

 

G

 

 

 

 

Y

 

 

Y/Y2

 

 

 

 

C

 

 

 

C

 

 

 

 

 

 

 

 

 

COMMON T’STAT CONNECTION

SINGLE STAGE HEATING

THERMOSTAT CONNECTIONS

ROOM

FURNACE

 

CONDENSING

THERMOSTAT

CONTROL

 

UNIT

 

R

 

 

 

R

 

TO AIR CONDITIONER

 

 

 

 

W

 

W1/W

 

CONTROLS

 

 

 

G

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

 

 

Y1

 

 

 

Y1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y2

 

 

Y/Y2

 

 

 

 

 

 

 

 

 

 

C

 

 

 

C

 

 

 

COMMON T’STAT CONNECTION

SINGLE STAGE HEATING AND TWO-STAGE COOLING

THERMOSTAT CONNECTIONS

FILTER PERFORMANCE

The airflow capacity data published in the “Blower Perfor- mance” table listed above represents blower performance WITHOUT filters. To determine the approximate blower per- formance of the system, apply the filter drop value for the fil- ter being used or select an appropriate value from the “Filter Performance” table shown below.

NOTE: The filter pressure drop values in the “Filter Perfor- mance” table shown below are typical values for the type of filter listed and should only be used as a guideline. Actual pressure drop ratings for each filter type vary between filter manufacturer.

FILTER PERFORMANCE - PRESSURE DROP INCHES W.C. AND (KPA)

 

Minimum Opening Size

 

 

 

 

 

Filter Type

 

 

 

 

 

Airflow Range

 

Disposable

 

WASHABLE FIBER*

 

 

Pleated

 

 

 

 

 

 

 

 

1 Opening

2 Openings

1 Opening

2 Opening

1 Opening

2 Opening

1 Opening

2 Opening

 

 

Sq. in.

Sq. in.

In w.c.

Pa

In w.c.

Pa

In w.c.

Pa

In w.c.

 

Pa

In w.c.

Pa

In w.c.

Pa

0 - 750

230

 

0.01

2.5

 

 

0.01

2.5

 

 

 

0.15

37

 

 

751 - 1000

330

 

0.04

10

 

 

0.03

7.5

 

 

 

0.20

50

 

 

1001 - 1250

330

 

0.08

20

 

 

0.07

17

 

 

 

0.20

50

 

 

1251 - 1500

330

 

0.08

20

 

 

0.07

17

 

 

 

0.25

62

 

 

1501 - 1750

380

658

0.14

35

0.08

20

0.13

32

0.06

 

15

0.30

75

0.17

42

1751 - 2000

380

658

0.17

42

0.09

22

0.15

37

0.07

 

17

0.30

75

0.17

42

2001 & Above

463

658

0.17

42

0.09

22

0.15

37

0.07

 

17

0.30

75

0.17

42

* Washable Fibers are the type supplied with furnace (if supplied.

APPLYING FILTER PRESSURE DROP TO DETERMINE SYSTEM AIRFLOW

To determine the approximate airflow of the unit with a filter in place, follow the steps below:

1.Select the filter type.

2.Select the number of return air openings or calculate the return opening size in square inches to determine the proper filter pressure drop.

3.Determine the External System Static Pressure (ESP) without the filter.

4.Select a filter pressure drop from the table based upon the number of return air openings or return air opening size and add to the ESP from Step 3 to determine the total system static.

5.If total system static matches a ESP value in the airflow table (i.e. 0.20, 0.60, etc,) the system airflow corre- sponds to the intersection of the ESP column and Model/ Blower Speed row.

Unitary Products Group

5