York TCGD12 THRU 60 warranty Condenser only Data, Unit AIR Handler, Cooling Rated NET MBH Model

Models: TCGD12 THRU 60

1 18
Download 18 pages 10.96 Kb
Page 6
Image 6

400034-YTG-B-0708

COOLING CAPACITY - With Air Handler Coils (Continued)

UNIT

AIR HANDLER

 

COIL

 

 

 

COOLING

 

 

 

 

 

RATED

 

NET MBH

 

 

MODEL

MODEL

 

W

MODEL1

 

SEER

EER

 

CFM

 

TOTAL

SENS.

 

 

 

 

 

 

 

 

 

 

 

13

SEER AC WITH AHP

/ SHP / F*FP

 

 

 

 

 

TCGD12S21S2(H)

AHP18

 

17

450

 

12.0

8.9

13.00

11.00

 

AHP18

 

17

650

 

18.0

12.6

13.00

11.00

TCGD18S21S2(H)

 

 

 

 

 

 

 

 

 

 

AHP24

 

17

650

 

18.0

12.6

13.00

11.00

 

F4FP024

 

18

600

 

18.0

12.6

1300

11.00

TCGD24S21S2(H)

AHP30

 

17

795

 

24.0

17.3

13.00

11.00

F4FP036

 

21.5

860

 

24.0

17.3

13.00

11.00

 

 

 

 

AHP30

 

17

1015

 

29.0

21.2

13.00

11.00

TCGD30S21S2(H)

 

 

 

 

 

 

 

 

 

 

AHP36

 

21

1015

 

29.0

21.2

13.00

11.00

 

F4FP040

 

21.5

1000

 

29.0

21.2

13.00

11.00

TCGD36S21S2(H)

AHP36

 

21

1235

 

35.0

24.4

13.00

11.00

F5FP048

 

24

1235

 

35.0

24.4

13.00

11.00

 

 

 

TCGD42S21S2(H)

AHP42

 

21

1485

 

42.0

29.4

13.00

11.00

F5FP048

 

24

1455

 

42.0

29.4

13.00

11.00

 

 

 

 

AHP/SHP60

 

24

1600

 

46.0

33.0

13.00

11.00

TCGD48S21S2(H)

 

 

 

 

 

 

 

 

 

 

F5FP048

 

24

1690

 

46.0

33.0

13.00

11.00

 

F5FP060

 

24

1680

 

46.0

33.0

13.00

11.00

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.

1.MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.

— = Not applicable.

CONDENSER ONLY DATA

 

Suct. T/P @ Compr.

 

 

 

Air Temp on Condenser

 

 

 

Model

 

75° F

 

95° F

 

115° F

 

 

 

 

 

 

Temp.

PSIG

MBH

 

KW

MBH

 

KW

MBH

 

KW

TCGD12S21S2(H)

40

68.6

11.81

 

0.73

8.15

 

0.85

5.29

 

1.01

SH 11 / SC 13 @

45

76.1

12.65

 

0.73

10.15

 

0.86

7.21

 

1.02

95 OD Temp

50

84.1

13.55

 

0.74

12.29

 

0.87

9.26

 

1.04

TCGD18S21S2(H)

40

68.6

17.53

 

1.07

15.03

 

1.29

11.98

 

1.57

SH 11 / SC 10 @

45

76.1

18.63

 

1.07

17.25

 

1.30

14.07

 

1.59

95 OD Temp

50

84.1

19.80

 

1.08

19.61

 

1.31

16.30

 

1.61

TCGD24S21S2(H)

40

68.6

22.88

 

1.42

19.07

 

1.70

13.99

 

2.02

SH 10 / SC 12 @

45

76.1

24.93

 

1.44

22.25

 

1.72

17.25

 

2.07

95 OD Temp

50

84.1

27.12

 

1.47

25.63

 

1.75

20.72

 

2.12

TCGD30S21S2(H)

40

68.6

28.77

 

1.75

23.85

 

2.01

17.06

 

2.21

SH 12 / SC 10 @

45

76.1

30.28

 

1.80

26.56

 

2.07

19.76

 

2.31

95 OD Temp

50

84.1

31.89

 

1.86

29.45

 

2.13

22.64

 

2.40

TCGD36S21S2(H)

40

68.6

31.46

 

2.16

18.41

 

2.37

13.42

 

2.78

SH 10 / SC 11 @

45

76.1

36.54

 

2.20

25.84

 

2.47

18.88

 

2.85

95 OD Temp

50

84.1

41.95

 

2.24

33.77

 

2.58

24.71

 

2.91

TCGD42S21S2(H)

40

68.6

40.44

 

2.46

28.86

 

2.83

21.78

 

3.21

SH 10 / SC 9 @ 95

45

76.1

45.28

 

2.52

36.10

 

2.91

27.55

 

3.30

OD Temp

50

84.1

50.44

 

2.59

43.82

 

3.00

33.70

 

3.41

TCGD48S21S2(H)

40

68.6

42.04

 

2.70

26.14

 

3.03

21.19

 

3.49

SH 10 / SC 12 @

45

76.1

46.86

 

2.77

35.10

 

3.16

27.59

 

3.60

95 OD Temp

50

84.1

52.00

 

2.85

44.65

 

3.30

34.43

 

3.73

TCGD60S21S2

40

68.6

52.76

 

3.40

46.38

 

4.04

36.26

 

5.08

SH 10 / SC 9 @ 95

45

76.1

59.98

 

3.41

53.35

 

4.14

42.46

 

5.15

OD Temp

50

84.1

67.69

 

3.41

60.79

 

4.25

49.07

 

5.22

6

Johnson Controls Unitary Products

Page 6
Image 6
York TCGD12 THRU 60 warranty Condenser only Data, Unit AIR Handler, Cooling Rated NET MBH Model, Seer EER CFM, TCGD60S21S2

TCGD12 THRU 60 specifications

The York TCGD12 THRU 60 is a highly efficient and versatile unit designed for commercial and industrial applications. This series of air-cooled chiller and heat pump systems is renowned for its reliability and advanced technologies, making it a popular choice among HVAC professionals.

One of the main features of the TCGD12 THRU 60 is its impressive energy efficiency. The unit employs a sophisticated design that significantly reduces energy consumption while maintaining optimal performance. The incorporation of variable speed compressors allows the system to adjust its cooling capacity according to the actual load, resulting in lower operating costs and enhanced energy savings.

Another notable characteristic is its use of environmentally friendly refrigerants. This series adheres to the latest industry standards, utilizing refrigerants that minimize environmental impact. This commitment to sustainability ensures that users can operate their systems with a reduced carbon footprint, aligning with modern regulations and corporate responsibility goals.

The TCGD12 THRU 60 also features a robust control system that simplifies operation and enhances performance monitoring. Advanced controls enable users to set customized operating parameters and schedule maintenance, improving the unit's longevity and reliability. With an intuitive interface, operators can easily manage system settings to optimize comfort and efficiency.

In terms of construction, the TCGD12 THRU 60 is built with durable materials designed to withstand harsh operating conditions. The exterior casing is weather-resistant, ensuring that the unit can perform reliably in varying climates. Additionally, the system's design promotes ease of installation and maintenance, reducing downtime and service costs.

Noise reduction is yet another defining feature of this series. The TCGD12 THRU 60 incorporates advanced sound-dampening technologies, allowing for quieter operation, making it suitable for sound-sensitive environments like schools, hospitals, and office buildings.

Lastly, the unit's versatility is paramount. With options for air or water-cooled systems, the TCGD12 can be tailored to fit different applications and installation requirements. Whether for cooling, heating, or both, this unit provides a comprehensive solution for modern HVAC needs. Overall, the York TCGD12 THRU 60 stands out for its efficiency, advanced technology, and robust design, representing a significant step forward in the field of commercial heating and cooling solutions.