400034-YTG-B-0708

COOLING PERFORMANCE DATA

AIR CONDITIONER MODEL NO.

TCGD30S21S2(H)

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

 

FC/MC/PC35

 

 

 

 

 

 

 

 

 

 

 

 

 

CONDENSING

IDCFM

 

 

 

800

 

 

 

 

1000

 

 

 

 

1200

 

 

ENTERING AIR

ID DB (°F)

80

80

 

75

80

80

80

80

75

80

80

80

80

75

80

80

TEMPERATURE

ID WB (°F)

57

62

 

62

67

72

57

62

62

67

72

57

62

62

67

72

 

T.C.

27.8

29.9

 

29.6

30.6

31.8

29.2

30.1

29.7

30.8

31.8

30.6

30.4

29.8

31.1

31.8

65

S.C.

27.2

24.5

 

20.5

19.0

14.8

28.2

26.1

21.6

20.0

15.4

29.1

27.7

22.6

21.0

15.9

 

KW

1.6

1.6

 

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.7

 

T.C.

26.2

28.2

 

27.9

29.7

31.2

28.0

28.9

28.2

30.0

31.2

29.9

29.5

28.6

30.3

31.2

75

S.C.

25.7

23.9

 

20.0

19.1

14.9

27.0

25.8

21.5

20.5

15.7

28.3

27.6

22.9

21.8

16.5

 

KW

1.8

1.8

 

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

 

T.C.

24.6

26.5

 

26.1

28.8

30.5

26.9

27.6

26.7

29.2

30.6

29.2

28.6

27.3

29.5

30.6

85

S.C.

24.1

23.3

 

19.4

19.2

14.9

25.8

25.4

21.4

20.9

16.0

27.4

27.5

23.3

22.7

17.1

 

KW

1.9

1.9

 

1.9

2.0

2.0

1.9

1.9

1.9

2.0

2.0

2.0

2.0

1.9

2.0

2.0

 

T.C.

23.0

24.9

 

24.4

28.0

29.8

25.7

26.3

25.3

28.4

29.9

28.4

27.7

26.1

28.7

30.0

95

S.C.

22.6

22.8

 

18.9

19.3

15.0

24.6

25.1

21.3

21.4

16.3

26.6

27.5

23.7

23.5

17.7

 

KW

2.1

2.1

 

2.1

2.1

2.2

2.1

2.1

2.1

2.1

2.2

2.1

2.1

2.1

2.1

2.2

 

T.C.

21.5

23.1

 

22.1

25.6

27.7

24.1

24.5

23.0

26.0

28.0

26.6

26.0

23.9

26.4

28.3

105

S.C.

21.2

21.3

 

17.9

18.5

14.3

23.0

23.4

20.0

20.6

15.8

24.8

25.5

22.1

22.7

17.2

 

KW

2.3

2.3

 

2.2

2.3

2.4

2.3

2.3

2.3

2.3

2.4

2.3

2.3

2.3

2.3

2.4

 

T.C.

20.1

21.4

 

19.8

23.2

25.5

22.5

22.9

20.8

23.7

26.0

24.9

24.3

21.8

24.1

26.5

115

S.C.

19.8

19.9

 

16.9

17.7

13.7

21.4

21.8

18.7

19.8

15.2

23.1

23.6

20.6

22.0

16.8

 

KW

2.4

2.4

 

2.4

2.5

2.5

2.5

2.5

2.4

2.5

2.6

2.5

2.5

2.5

2.5

2.6

 

T.C.

18.7

19.7

 

17.6

20.9

23.4

20.9

21.2

18.6

21.4

24.1

23.1

22.7

19.7

21.9

24.8

125

S.C.

18.4

18.6

 

15.9

16.8

13.1

19.9

20.1

17.5

19.0

14.7

21.4

21.7

19.1

21.3

16.4

 

KW

2.6

2.6

 

2.5

2.6

2.7

2.6

2.6

2.6

2.7

2.7

2.7

2.7

2.6

2.7

2.8

NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

Air Handler

Coil

T.C.

S.C.

KW

FC/MC/PC32

1.00

1.00

1.00

FC/MC/PC37

1.00

1.00

1.00

FC/MC/PC43

1.00

1.00

1.00

HC36

1.00

1.00

1.00

HC42

1.00

1.00

1.00

AHP30

1.00

1.00

1.00

AHP36

1.00

1.00

1.00

AV36

1.02

1.03

0.89

F4FP040

1.00

1.00

1.00

MA12B

FC/MC35B

1.00

1.00

1.00

MA12B

FC/MC43B

1.00

1.00

1.00

MV12B

FC/MC43B

1.02

1.02

0.89

MV16C

FC/MC43C

1.02

1.02

0.89

MV12B

FC/MC35B

1.02

1.02

0.89

MV16C

FC/MC35C

1.02

1.02

0.89

Variable Speed

Coil

T.C.

S.C.

KW

Furnace

 

 

 

 

PV8*A12

FC/MC/PC32A

1.00

1.00

0.91

PV9*A12

FC/MC/PC32A

1.00

1.00

0.91

PV8*B16

FC/MC/PC35B

1.02

1.02

0.89

PV8*C16

FC/MC/PC35C

1.02

1.02

0.89

PV8*C20

FC/MC/PC35B

1.02

1.03

0.89

P(C,V)9*B12

FC/MC/PC35C

1.02

1.01

0.89

PV9*A12

FC/MC/PC35A

1.00

1.00

0.91

PV8*A12

FC/MC/PC37A

1.02

1.02

0.89

PV9*A12

FC/MC/PC37A

1.02

1.02

0.89

PV8*B16

FC/MC/PC43B

1.02

1.02

0.89

PV8*C16

FC/MC/PC43C

1.02

1.02

0.89

PV8*C20

FC/MC/PC43C

1.02

1.03

0.89

P(C,V)9*B12

FC/MC/PC43B

1.02

1.01

0.89

P(C,V)9*C16

FC/MC/PC43C

1.02

1.01

0.89

P(C,V)9*C20

FC/MC/PC43C

1.02

1.01

0.89

PV8*B16

HC36

1.02

1.02

0.89

P(C,V)9*B12

HC36

1.02

1.01

0.89

PV8*C16

HC42

1.02

1.03

0.89

PV8*C20

HC42

1.02

1.03

0.89

P(C,V)9*C16

HC42

1.02

1.01

0.89

P(C,V)9*C20

HC42

1.02

1.01

0.89

14

Johnson Controls Unitary Products

Page 14
Image 14
York TCGD12 THRU 60 FC/MC/PC32 FC/MC/PC37 FC/MC/PC43, AHP30 AHP36, MA12B FC/MC35B FC/MC43B MV12B MV16C FC/MC43C FC/MC35C

TCGD12 THRU 60 specifications

The York TCGD12 THRU 60 is a highly efficient and versatile unit designed for commercial and industrial applications. This series of air-cooled chiller and heat pump systems is renowned for its reliability and advanced technologies, making it a popular choice among HVAC professionals.

One of the main features of the TCGD12 THRU 60 is its impressive energy efficiency. The unit employs a sophisticated design that significantly reduces energy consumption while maintaining optimal performance. The incorporation of variable speed compressors allows the system to adjust its cooling capacity according to the actual load, resulting in lower operating costs and enhanced energy savings.

Another notable characteristic is its use of environmentally friendly refrigerants. This series adheres to the latest industry standards, utilizing refrigerants that minimize environmental impact. This commitment to sustainability ensures that users can operate their systems with a reduced carbon footprint, aligning with modern regulations and corporate responsibility goals.

The TCGD12 THRU 60 also features a robust control system that simplifies operation and enhances performance monitoring. Advanced controls enable users to set customized operating parameters and schedule maintenance, improving the unit's longevity and reliability. With an intuitive interface, operators can easily manage system settings to optimize comfort and efficiency.

In terms of construction, the TCGD12 THRU 60 is built with durable materials designed to withstand harsh operating conditions. The exterior casing is weather-resistant, ensuring that the unit can perform reliably in varying climates. Additionally, the system's design promotes ease of installation and maintenance, reducing downtime and service costs.

Noise reduction is yet another defining feature of this series. The TCGD12 THRU 60 incorporates advanced sound-dampening technologies, allowing for quieter operation, making it suitable for sound-sensitive environments like schools, hospitals, and office buildings.

Lastly, the unit's versatility is paramount. With options for air or water-cooled systems, the TCGD12 can be tailored to fit different applications and installation requirements. Whether for cooling, heating, or both, this unit provides a comprehensive solution for modern HVAC needs. Overall, the York TCGD12 THRU 60 stands out for its efficiency, advanced technology, and robust design, representing a significant step forward in the field of commercial heating and cooling solutions.