413437-YTG-C-0908

COOLING CAPACITY - YCJF42S41S1 With Variable Speed Furnaces (Continued)

VARIABLE SPEED

COIL

 

 

 

COOLING

 

 

FURNACE MODEL

MODEL1

W

RATED

Net MBH

SEER

EER

 

CFM

TOTAL

SENS.

 

 

 

 

 

 

14.5 SEER AC WITH VARIABLE SPEED FURNACES2

 

 

 

Y*(8,L)C*B12

HD48

17

1350

41.0

29.8

14.75

12.50

Y*(8,L)C*C16

HD48

21

1435

41.5

30.8

15.25

13.00

Y*(8,L)C*C20

HD48

21

1410

42.0

31.0

15.25

13.00

Y*9C*B12

HD48

17

1150

40.0

28.2

14.75

12.50

Y*9C*C16

HD48

21

1395

41.5

30.8

15.00

12.75

Y*9C*C20

HD48

21

1430

41.5

30.8

14.75

12.50

Y*9C*D20

HD48

24

1450

41.5

30.8

15.00

12.75

Y*(8,L)C*C16

HD60

21

1420

42.0

31.4

15.55

13.30

Y*(8,L)C*C20

HD60

21

1410

42.0

31.4

15.85

13.50

Y*9C*C16

HD60

21

1445

42.0

31.2

14.85

12.75

Y*9C*C20

HD60

21

1445

42.0

31.4

15.20

13.00

Y*9C*D20

HD60

24

1445

42.0

31.4

15.40

13.15

Y*(8,L)C*C16

UC48C

21

1435

40.5

30.8

14.90

12.65

Y*(8,L)C*C20

UC48C

21

1410

40.5

31.0

15.10

12.80

Y*9C*C16

UC48C

21

1395

40.0

30.8

14.70

12.45

Y*9C*C20

UC48C

21

1430

40.0

30.8

14.60

12.40

Y*9C*D20

UC48D

24

1450

40.0

30.8

14.80

12.60

Y*(8,L)C*C16

UC60C

21

1420

40.5

29.8

15.00

12.75

Y*(8,L)C*C20

UC60C

21

1410

40.5

30.0

15.30

13.00

 

 

 

 

 

 

 

 

Y*9C*C16

UC60C

21

1445

40.0

29.6

14.35

12.25

Y*9C*C20

UC60C

21

1445

40.5

29.6

14.65

12.50

Y*9C*D20

UC60D

24

1445

40.5

29.8

14.90

12.65

G*9V*C16

FC/MC/PC43C

21

1360

41.0

30.8

14.50

12.50

G*9V*C20

FC/MC/PC43C

21

1395

41.5

30.8

14.50

12.50

G*9V*C16

FC/MC/PC48C

21

1395

42.0

31.4

15.25

13.00

G*9V*C20

FC/MC/PC48C

21

1430

42.0

31.4

15.00

12.75

G*9V*D20

FC/MC/PC48D

24

1450

42.0

31.4

15.25

13.00

G*9V*D20

FC/MC/PC60D

24

1445

42.0

31.2

15.30

13.05

G*9V*D20

FC/MC62D

24

1455

42.0

31.6

15.50

13.20

G*9V*C16

FC/PC60C

21

1445

41.5

31.0

14.75

12.60

G*9V*C20

FC/PC60C

21

1445

41.5

31.2

15.10

12.90

G*9V*C16

HC42

21

1360

41.0

30.8

14.75

12.50

G*9V*C20

HC42

21

1395

41.5

30.8

14.75

12.50

G*9V*B12

HD48

17

1150

40.0

28.2

14.75

12.50

G*9V*C16

HD48

21

1395

41.5

30.8

15.00

12.75

G*9V*C20

HD48

21

1430

41.5

30.8

14.75

12.50

G*9V*D20

HD48

24

1450

41.5

30.8

15.00

12.75

G*9V*C16

HD60

21

1445

42.0

31.2

14.85

12.75

G*9V*C20

HD60

21

1445

42.0

31.4

15.20

13.00

G*9V*D20

HD60

24

1445

42.0

31.4

15.40

13.15

G*9V*C16

UC48C

21

1395

40.0

30.8

14.70

12.45

G*9V*C20

UC48C

21

1430

40.0

30.8

14.60

12.40

G*9V*D20

UC48D

24

1450

40.0

30.8

14.80

12.60

G*9V*C16

UC60C

21

1445

40.0

29.6

14.35

12.25

G*9V*C20

UC60C

21

1445

40.5

29.6

14.65

12.50

G*9V*D20

UC60D

24

1445

40.5

29.8

14.90

12.65

1.MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.

2.Variable speed furnaces have B.O.D (Blower on Delay) standard.

16

Johnson Controls Unitary Products

Page 16
Image 16
York YCJF24 warranty UC48C