York YUHC 07-18 Operating Temperature, Cautions, Outdoor Unit Multi Inverter RRJC, 8ENGLISH

Models: YUHC 18-60 YUHC 07-18

1 23
Download 23 pages 11.11 Kb
Page 8
Image 8
Outdoor Unit Multi Inverter RRJC 18-27

Outdoor Unit Multi Inverter RRJC 18-27

Model

 

 

RRJC 18AA-AAA

 

 

RRJC 27AA-AAA

 

Indoor Units Combination

 

Single

 

Double

Single

 

Double

 

Treble

Power supply

 

Ph-V-Hz

1Ph, 220-240V~, 50Hz

 

1Ph, 220-240V~, 50Hz

 

 

Capacity

Btu/h

7,000~12,000

 

18,000

7,000~12,000

 

16,000~24,000

 

27,000

Cooling

W

2,050~3,517

 

5,275

2,000~3,500

 

4,690~7,000

 

7,913

 

 

 

 

Input

W

1,000~1,300

 

1,813

1,000~1,300

 

2,570~2,850

 

2,806

 

 

 

 

 

Rated current

A

4.8~6.5

 

11.5

4.8~6.5

 

11.7~13.5

 

13.5

 

Capacity

Btu/h

9,000~14,000

 

21,000

10,000~14,000

 

24,000~27,000

 

30,000

Heating

W

2,638~4,103

 

6,155

2,900~4,100

 

7,000~7,900

 

8,792

 

 

 

 

Input

W

1,300~1,600

 

2,038

1,300~1,600

 

2,100~2,750

 

2,739

 

 

 

 

 

Rated current

A

6.3~7.8

 

11.0

6.3~7.8

 

11.0~13.2

 

13.2

Max. input

 

W

3,200

 

 

3,200

 

 

Max. current

 

A

20

 

 

20

 

 

 

Type

 

Rotary inverter

 

 

Rotary inverter

 

 

Input

W

1,690

 

 

1,690

 

 

 

Rated current (RLA)

A

11.6

 

 

11.6

 

 

Compressor

Locked rotor Amp (LRA)

A

60

 

 

60

 

 

 

Thermal protector

 

Internal

 

 

 

Internal

 

 

Capacitor

µF

85µF/250V

 

 

 

85µF/250V

 

 

Refrigerant oil

ml

750

 

 

750

 

 

Outdoor fan

Input

W

148

 

 

148

 

 

Capacitor

µF

3

 

 

3

 

 

motor

 

 

 

 

Speed

r/min

775

 

 

775

 

 

 

 

 

 

 

 

Number of rows

 

2

 

 

2

 

 

 

Fin spacing

mm

1.7

 

 

1.7

 

 

 

Fin type

 

Hydrophilic aluminium

 

Hydrophilic aluminium

 

Outdoor coil

Tube outside dia.

mm

Ø9.53

 

 

Ø9.53

 

 

 

Tube Material

 

Innergroove tube

 

 

Innergroove tube

 

 

Coil length x height x width

mm

776×660×22

 

776×660×22

 

 

 

Number of circuits

 

2

 

 

2

 

 

Outdoor air flow

m3/h

2,500

 

 

2,500

 

 

Outdoor noise level

dB(A)

60

 

 

60

 

 

Outdoor

Dimension (WxHxD)

mm

845X695X335

 

 

845X695X335

 

Packing (WxHxD)

mm

965X772X405

 

 

965X772X405

 

unit

 

 

 

Net/Gross weight

kg

71/74

 

 

72/76

 

 

 

 

 

 

 

Refrigerant Type R-410A

g

2,100

 

 

2,250

 

 

 

Liquid side/ Gas side

mm

Ø6.35/Ø9.53

 

 

3 X Ø6.35/Ø9.53

 

Refrigerant

Transfer Connector (9.5312.7)

mm

2

 

 

2

 

 

piping

Max. refrigerant pipe length

m

15 (each indoor unit)

 

15 (each indoor unit)

 

 

Max. difference in level

m

10 (each indoor unit)

 

10 (each indoor unit)

 

Remark : The above design and specifications are subject to change without prior notice for product improvement.

OPERATING TEMPERATURE

Temperature

Mode

Cooling operation

Heating operation

Drying operation

 

 

 

 

 

Room temperature

 

17°C~32°C

0°C~30°C

17°C~30°C

Outdoor temperature

 

21°C~43°C

-7°C~24°C

11°C~43°C

CAUTIONS

1.If air conditioner is used outside of the above conditions, certain safety protection features may come into operation cause the unit to function abnormally.

2.Room relative humidity less than 80%. If the air conditioner operates in excess of this figure, the surface of the air conditioner may attract condensation. Please set the vertical air flow louver to its maximum angle (Vertically to the floor), and set HIGH fan mode.

3.Optimum performance will be achieved within these operating temperature.

8ENGLISH

J368-EN.indd 8

2/1/07 9:40:57 AM

Page 8
Image 8
York YUHC 07-18, YUHC 18-60 owner manual Operating Temperature, Cautions, Outdoor Unit Multi Inverter RRJC, 8ENGLISH