DC Inverter R-410A
mm
MODEL A | B | C | D | E | H | REMARK |
H
18 840 560 335 360 310 677
24 894 590 333 355 302 860
A | 36 | 990 | 624 | 366 | 396 | 340 | 960 |
|
48 940 600 376 400 340 1,245
B
D C | E |
PREPARATION BEFORE INSTALLATION
•Before doing any work, check the interior power supply cord and the main breaker capacity are sufficient and the installation area is sufficient and complies with the requirements.
•Check that the power supply available agrees with name plate voltage.
•Electrical work, wiring and cables must be performed in compliance with national and local wiring codes and standard.
•Do not use the extension cables. In the case extended cables are needed, use the terminal block.
INSTALLATION
■Installation place
The indoor unit must be installed such that there is no short circuit of the cool discharge. Comply to the installation clearance recommended. Do not put the indoor unit where there is direct sunlight on unit. Make sure the location is suitable for piping and drainage.
INDOOR UNIT
YUKC 07-12
|
| Air Outlet |
210 | 102 | 87 |
25715
870
915
870
268 | 380 |
380
220
|
| 175 |
55 |
| 210 |
|
| |
|
| 63 |
|
| Drain port Ø25 |
Refrigerant pipe |
| Refrigerant pipe |
Gas Side Ø9.0 |
| Liquid Side Ø9.53 |
148 |
| >250mm |
100 | Ø100 | |
|
| |
Fresh |
|
|
air inlet |
|
|
>500mm |
| >500mm |
10ENGLISH