Wiring Diagram

L

1

A

0

2

3

4

220/240

5

6

B

N

A. IGNITOR SWITCH

B. IGNITOR UNIT

Fault Finding

Preliminary Electrical Systems

PLUG (with cover

 

 

 

 

 

 

 

 

Check

 

 

removed)

 

 

 

 

Earth Wire

(

)

Brown

Blue

 

 

Green/Yellow

 

 

Green

START

 

 

 

 

 

 

FUSE

 

 

 

 

 

 

Yellow

Isolate appliance

 

 

 

 

 

and carry out:

 

 

 

 

 

 

A: Earth Continuity

Neutral Wire

 

 

 

 

 

check.

Blue

 

 

SOCKET

(face view)

E()

NL

 

 

 

 

 

 

 

 

 

 

 

Blue

 

 

 

 

 

 

 

Brown

 

Green

 

 

 

 

 

 

 

 

 

 

 

Yellow

 

 

 

Carry out:

 

Electricity supply

 

 

 

NO

YES

Carry out:

 

 

 

 

 

 

D: Resistance to

 

 

should now be

 

 

 

 

 

 

C: Polarity check.

 

 

 

 

 

 

 

 

 

 

Earth check.

 

satisfactory.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Has inlet fuse blown?

NO

YES

Inlet wiring

faulty.

Rectify any

fault.

Isolate appliance and carry out:

B:Insulation check. Rectify any fault including replacing fuses as necessary.

A. EARTH CONTINUITY CHECK - Appliance must be electrically disconnected - meter set on W (Ohms) x 1 scale and adjust zero if necessary.

a)Test leads from any appliance earth point to earth pin on plug. Resistance should be less than 0.1 ý (Ohm), check all earth wires for continuity and all contacts are clean and tight.

B. INSULATION CHECK - Appliance electrically disconnected, all switches ON.

a)meter set on W(Ohms) x 1 scale.

Test leads from L to N in appliance terminal block. If meter reads «0» then there is a short circuit.

b)meter set on W (Ohm) x 100 scale.

Repeat test with leads from L to E. If meter reads less than × (infinity) there is a fault.

NOTE - Should it be found that the fuse has failed but no fault is indicated - a detailed continuity check (i.e. by disconnecting and checking each component) is required to trace the faulty component. It is possible that a fault could occur as a result of local burning/arcing but no fault could be found under test. However a detailed visual inspection should reveal evidence of burning around the fault.

13

Page 13
Image 13
Zanussi GAS HOB manual Wiring Diagram, Fault Finding, Preliminary Electrical Systems, Check