Instructions for the Installer

Engineers technical data

OVERALL DIMENSIONS

Width:

580 mm.

Depth:

500 mm.

CUT OUT DIMENSIONS

Width:

550 mm.

Depth:

470 mm.

Thickness:

30 mm.

SUPPLY CONNECTIONS

Gas:

RC 1/2 inch (1/2 inch male) Rear right hand corner

Electric:

230-240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.

Ignition HT Spark

 

 

 

Spark Generator

Ispra Control's BF 50066 - 230-240V

0.6 YA T 120

 

Spark Gap

Fixed

 

 

Rear Left Burner (semi-rapid)

Rear Right Burner (semi-rapid)

Heat Input

2.0 kW (6824 BTU/HR)

Heat Input

2.0 kW (6824 BTU/HR)

Front Left Burner (rapid)

Front Right Burner (auxiliary)

Heat Input

3.0 kW (10236 BTU/HR)

Heat Input

1.0 kW (3412 BTU/HR)

2.8 kW L.P.G. (9554 BTU/HR)

TYPE OF

 

 

BURNER

 

RAPID

SEMI-RAPID

AUXILIARY

GAS

Characteristics

 

 

(large)

(medium)

(small)

 

 

 

 

 

 

 

 

 

POSITION

 

MAX

MIN

MAX

MIN

MAX

MIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

NATURAL GAS

 

VALUE = 37.78 MJ/m Ws - 50.7 MJ/ m3

NOMINAL THERMAL

 

 

 

 

 

 

20 mbar

POWER

kW

3.0

0.65

2.0

0.45

1.0

0.33

NOMINAL FLOW

 

 

 

 

 

 

 

RATE

m3/h

0.286

0.057

0.190

0.038

0.095

0.028

NOZZLE REFERENCE

119

Adjust.

9 6

Adjust.

7 0

Adjust.

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28-30/37 mbar

VALUE = 49.92 MJ/Kg

NOMINAL THERMAL

 

 

 

 

 

 

LPG GAS

POWER

kW

2.8

0.65

2.0

0.45

1.0

0.33

NOMINAL FLOW

 

 

 

 

 

 

 

RATE

g/h

202

43.5

144

2 9

7 2

21.5

NOZZLE REFERENCE

8 6

4 0

7 1

3 2

5 0

2 8

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

Dia. Tap By-pass

 

1/100 mm

Auxiliary

28

Semi-rapid

32

Rapid

40

Aeration adjustment none

APPLIANCE CLASS: 3

APPLIANCE CATEGORY: II2H3+

APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar