White Rodgers 1F95EZ-0671 specifications INSTALLER/CONFIGURATION Menu

Models: 1F95EZ-0671

1 8
Download 8 pages 4.93 Kb
Page 5
Image 5

INSTALLER/CONFIGURATION MENU

With Heat or A/C selected, press and hold the Menu button for at least 5 seconds. The display will show item #1 in the

table below. Press Menu to advance to the next menu item. Press or to change a menu item options.

INSTALLER/CONFIGURATION MENU

Menu

HP

SS

Press

Displayed

Press

or

to

Comments

Ref.

 

 

Button

(Factory Default)

select from listed op-

 

 

 

 

 

 

 

tions

 

 

1

1

1

MENU

(MS 2)

HP 1, HP 2, SS 1

Selects Multi-Stage (MS 2 No Heat Pump),

 

 

 

 

 

 

 

 

Heat Pump 1 (HP 1, 1 compressor),

 

 

 

 

 

 

 

 

Heat Pump 2 (HP 2, 2 compressor or 2 speed

 

 

 

 

 

 

 

 

compressor), or Single Stage (SS 1)

 

 

 

 

 

 

 

 

2

2

2

MENU

(GAS) for SS or MS

ELE or GAS

 

GAS setting: furnace controls the blower

 

 

 

 

(ELE) for HP1, HP2

 

 

 

ELE setting: thermostat controls the blower

 

 

 

 

 

 

 

 

 

3

3

3

MENU

(On) E

 

OFF

 

Selects Energy Management Recovery (EMR)

 

 

 

 

 

 

 

 

On or OFF. (Not available in -non-program-

 

 

 

 

 

 

 

 

mable mode)

4

4

MENU

(ME) Cr Heat

 

SL, FA

 

Selects Adjustable Anticipation, cycle rate, Heat

 

 

 

 

 

 

 

 

(This item only appears when MS 2 or SS 1 is

 

 

 

 

 

 

 

 

selected above)

5

4

MENU

(ME) Cr Heat A/C

 

SL, FA

 

Selects Adjustable Compressor Anticipation

 

 

 

 

 

 

 

 

(Heat Pump) this item only appears when

 

 

 

 

 

 

 

 

HP 1, HP 2 is selected above

6

5

5

MENU

(ME) Cr A/C

 

SL, FA

 

Selects Adjustable Anticipation, cycle rate, cool

 

 

 

 

or

 

 

 

(when MS 2 or SS 1 is selected above) or

 

 

 

 

(FA) Cr Aux Heat

 

SL

 

Selects the cycle rate for Auxiliary stage (when

 

 

 

 

 

 

 

 

HP 1 or HP 2 is selected above)

 

 

 

 

 

 

 

 

 

7

6

6

MENU

(OFF) CL

 

On

 

Selects Compressor Lockout Off or On

 

 

 

 

 

 

 

 

8

7

7

MENU

Heat A/C Off

Heat A/C Off,

 

System Mode Configuration

 

 

 

 

or

Heat Off with Fan icon,

 

 

 

 

 

Aux Heat A/C Off

Heat Off without Fan icon

 

 

 

 

 

 

 

A/C Off

 

 

 

 

 

 

 

 

 

 

 

9

8

8

MENU

(OFF) CO

 

On

 

Selects Compressor Optimization

 

 

 

 

 

 

 

 

 

10

9

9

MENU

(On) dL

 

OFF

 

Selects Display Light On or OFF

 

 

 

 

 

 

 

11

10

10

MENU

0 HI

1 HI, 2 HI, 3HI, 4 HI,

Adjustable Ambient Temperature Display

 

 

 

 

(current temperature)

1 LO, 2 LO, 3 LO, 4 LO

 

 

 

 

 

 

 

 

 

 

12

11

11

MENU

°F

 

°C

 

Selects Fahrenheit/Celsius Temperature Display

 

 

 

 

(current temperature)

 

 

 

 

13

12

12

MENU

(0) P

 

7

 

Defaults to P (0) non-programmable

 

 

 

 

 

 

 

 

P (7) is 7-day programming

 

 

 

 

 

 

 

 

 

14

13

13

MENU

PS (2)

 

4

 

Selects Program periods per day:

 

 

 

 

Day, Night

Morn, Day, Eve, Night

4 = Morn, Day, Eve, Night

 

 

 

 

 

 

 

 

2 = Day, Night

 

 

 

 

 

 

 

 

(Skipped if non-programmable)

15

14

MENU

(On) Heat FA

 

OFF

 

Fast Heat option may be disabled by

 

 

 

 

 

 

 

 

selecting OFF. NA to SS or HP1 config.

 

 

 

 

 

 

 

 

 

16

15

14

MENU

(On) FA A/C

 

OFF

 

Fast Cool option may be disabled by

 

 

 

 

 

 

 

 

selecting OFF. NA to SS or HP1 config.

 

 

 

 

 

 

 

 

 

17

16

15

MENU

(On) dS

 

Off

 

Selects Automatic Daylight Saving Time option

 

 

 

 

 

 

 

 

 

18

17

16

MENU

(99) HL Heat

 

62 to 98

 

Select's Limited HEAT Range

 

 

 

 

 

 

 

 

 

19

18

17

MENU

(45) LL A/C

 

46 to 82

 

Select's Limited A/C Range

 

 

 

 

 

 

 

 

 

20

19

MENU

(0) dF

 

1 to 9

 

Selects dF (Dual Fuel) setting. 0 is Off

 

 

 

 

 

 

 

 

(If Dual Fuel option is required, a selection of 5

 

 

 

 

 

 

 

 

is recommended)

 

 

 

MENU

(60) Cd

 

0 to 99

 

Selects compressor delay in seconds when dF

 

 

 

 

 

 

 

 

is greater than 0

21

20

18

MENU

(o) A/C On

 

Heat (b)

 

Selects operation of the reversing valve terminal

 

 

 

 

 

 

 

 

(O/B) output as an O or B terminal

22

21

19

MENU

 

 

 

 

Returns to Normal Operation

 

 

 

 

 

 

 

 

 

5

Page 5
Image 5
White Rodgers 1F95EZ-0671 specifications INSTALLER/CONFIGURATION Menu

1F95EZ-0671 specifications

The White Rodgers 1F95EZ-0671 is an advanced programmable thermostat designed to offer convenience and control over home heating and cooling systems. It is an ideal choice for homeowners looking to optimize their energy usage while maintaining comfortable living conditions.

One of the standout features of the 1F95EZ-0671 is its user-friendly interface, which includes a large, easy-to-read touchscreen display. The intuitive design allows users to navigate through settings effortlessly, making it accessible for individuals of all ages. The display is backlit, ensuring visibility even in low light conditions, which adds to its ease of use.

This thermostat supports both heating and cooling systems, including conventional systems as well as heat pumps, making it versatile for various home setups. Its compatibility with 24V systems further enhances its appeal for homeowners looking to upgrade their existing thermostats without extensive modifications.

Another significant technological advancement in the 1F95EZ-0671 is its Wi-Fi connectivity. This feature allows users to control their home climate remotely via a smartphone app, providing unparalleled convenience. Whether at work or on vacation, users can adjust their home temperature settings, ensuring optimal comfort upon their return. The app also enables users to monitor energy usage, helping them make informed decisions about their heating and cooling practices.

Energy efficiency is a key focus of the 1F95EZ-0671. It features a 7-day programmable schedule, allowing users to set heating and cooling times based on their specific routines. By programming temperature changes for different times of the day, users can significantly reduce energy consumption and lower utility bills. The thermostat also includes a vacation mode, which temporarily overrides the regular schedule, further optimizing energy savings when the home is unoccupied.

Additionally, the 1F95EZ-0671 is equipped with Smart Alerts that notify users of extreme temperatures, helping to prevent potential problems and ensure a safe home environment. With its combination of advanced features and user-centric design, the White Rodgers 1F95EZ-0671 provides an effective solution for modern temperature control, making it a valuable addition to any home.