Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATINGTHIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.
Blue Easy Reader Thermostat
Single Stage,
Model | Programming Choices | |
|
|
|
7 Day | ||
|
|
|
APPLICATIONS
THERMOSTAT APPLICATION GUIDE |
|
| ||
|
|
|
| |
Thermostat | Thermostat |
| Maximum | |
| Stages |
| ||
Configuration Options | Applications |
|
| |
| Heat/Cool |
| ||
|
|
|
| |
Single Stage 1 | Gas, Oil, Electric, Heat Only, |
| 1/1 |
|
No Heat Pump (SS1) | Cool Only or Heat/Cool |
|
| |
|
|
| ||
| Systems, 2 or 3 wire Hydronic |
|
|
|
|
|
|
| |
Multi Stage 2 | Zone (Hot Water or Steam) |
| 2/2 |
|
No Heat Pump (MS2) | Systems, 24 Volt or Millivolt |
|
| |
|
|
| ||
|
|
|
|
|
Heat Pump 1 | Single Stage Compressor |
|
|
|
Single Stage Compressor | Heat Pump Systems - up to 2 |
| 3/1 |
|
Heat Pump (HP1) | Stages Aux./Emergency Heat |
|
|
|
|
|
|
|
|
Heat Pump 2 | Two Stage or Two Compressor |
|
|
|
Two Stage or Two |
|
|
| |
Heat Pump systems - up to 2 |
| 4/2 |
| |
Compressor Heat Pump |
|
| ||
Stages Aux./Emergency Heat |
|
|
| |
(HP2) |
|
|
| |
|
|
|
| |
|
|
|
|
|
SPECIFICATIONS
Electrical Rating: |
|
|
|
Battery Power | mV to 30 VAC, NEC Class II, 50/60 Hz or DC | ||
20 to 30 VAC |
| ||
Terminal Load | 1.5A per terminal, 2.5A maximum all terminals combined | ||
Setpoint Range | 45 to 99°F (7 to 32°C) | ||
Rated Differentials: | Fast | Med. | Slow |
Heat (Single Stage/Multi Stage) | 0.4 °F | 0.6 °F | 1.7 °F |
Cool (Single Stage/Multi Stage) | 0.9 °F | 1.2 °F | 1.7 °F |
Heat Pump | 0.9 °F | 1.2 °F | 1.7 °F |
Aux. Heat | 0.6 °F | – | 1.7 °F |
Operating Ambient | 32°F to +105°F (0 to +41°C) | ||
Operating Humidity | 90% | ||
Shipping Temperature Range | |||
Dimensions Thermostat | |||
|
|
|
|
!CAUTION
To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.
Index | Page |
Installation | 2 |
Wiring Connections | 2 |
Wiring Diagrams | 3 |
Thermostat Quick Reference | 4 |
Installer Configuration Menu | 5 |
Operating Your Thermostat | 7 |
Troubleshooting | 8 |
ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this product may replace a product that contains mercury.
Mercury and products containing mercury must not be discarded in household trash. Do not touch any spilled mercury. Wearing
| PART NO. |
Replaces | |
www.emersonclimate.com | 1023 |