FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATINGTHIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

Blue Easy Reader Thermostat

Single Stage, Multi-Stage, Heat Pump Installation Instructions for Model:

Model

Programming Choices

 

 

 

1F95EZ-0671

Non-Programmable

7 Day

 

 

 

APPLICATIONS

THERMOSTAT APPLICATION GUIDE

 

 

 

 

 

 

1F95EZ-0671 Thermostat

Thermostat

Thermostat

 

Maximum

 

Stages

 

Configuration Options

Applications

 

 

 

Heat/Cool

 

 

 

 

 

Single Stage 1

Gas, Oil, Electric, Heat Only,

 

1/1

 

No Heat Pump (SS1)

Cool Only or Heat/Cool

 

 

 

 

 

 

Systems, 2 or 3 wire Hydronic

 

 

 

 

 

 

 

Multi Stage 2

Zone (Hot Water or Steam)

 

2/2

 

No Heat Pump (MS2)

Systems, 24 Volt or Millivolt

 

 

 

 

 

 

 

 

 

 

Heat Pump 1

Single Stage Compressor

 

 

 

Single Stage Compressor

Heat Pump Systems - up to 2

 

3/1

 

Heat Pump (HP1)

Stages Aux./Emergency Heat

 

 

 

 

 

 

 

 

Heat Pump 2

Two Stage or Two Compressor

 

 

 

Two Stage or Two

 

 

 

Heat Pump systems - up to 2

 

4/2

 

Compressor Heat Pump

 

 

Stages Aux./Emergency Heat

 

 

 

(HP2)

 

 

 

 

 

 

 

 

 

 

 

 

SPECIFICATIONS

Electrical Rating:

 

 

 

Battery Power

mV to 30 VAC, NEC Class II, 50/60 Hz or DC

Input-Hardwire

20 to 30 VAC

 

Terminal Load

1.5A per terminal, 2.5A maximum all terminals combined

Setpoint Range

45 to 99°F (7 to 32°C)

Rated Differentials:

Fast

Med.

Slow

Heat (Single Stage/Multi Stage)

0.4 °F

0.6 °F

1.7 °F

Cool (Single Stage/Multi Stage)

0.9 °F

1.2 °F

1.7 °F

Heat Pump

0.9 °F

1.2 °F

1.7 °F

Aux. Heat

0.6 °F

1.7 °F

Operating Ambient

32°F to +105°F (0 to +41°C)

Operating Humidity

90% non-condensing max.

Shipping Temperature Range

-40 to +150°F (-40 to +65°C)

Dimensions Thermostat

4-3/16"H x 6-1/2"W x 1-5/8"D

 

 

 

 

!CAUTION

To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.

Index

Page

Installation

2

Wiring Connections

2

Wiring Diagrams

3

Thermostat Quick Reference

4

Installer Configuration Menu

5

Operating Your Thermostat

7

Troubleshooting

8

ATTENTION: MERCURY NOTICE

This product does not contain mercury. However, this product may replace a product that contains mercury.

Mercury and products containing mercury must not be discarded in household trash. Do not touch any spilled mercury. Wearing non-absorbent gloves, clean up any spilled mercury and place in a sealed container. For proper disposal of a product containing mercury or a sealed container of spilled mercury, place it in a suitable shipping container. Refer to www.white-rodgers.comfor location to send product containing mercury.

 

PART NO. 37-6986B

www.white-rodgers.com

Replaces 37-6986A

www.emersonclimate.com

1023

Page 1
Image 1
White Rodgers 1F95EZ-0671 specifications Applications, Specifications, Save these instructions for future use