With EPROM, IndustryPack, and SIMs installed and headers properly configured, proceed as follows to install the MVME162 in the VME chassis:

1.Turn all equipment power OFF and disconnect the power cable from the AC power source.

Caution

!

WARNING

Inserting or removing modules while power is applied could result in damage to module components.

Dangerous voltages, capable of causing death, are present in this equipment. Use extreme caution when handling, test- ing, and adjusting.

2.Remove the chassis cover as instructed in the user’s manual for the equipment.

3.Remove the filler panel from the card slot where you are going to install the MVME162.

If you intend to use the MVME162 as system controller, it must occupy the leftmost card slot (slot 1). The system controller must be in slot 1 to correctly initiate the bus-grant daisy-chain and to ensure proper operation of the IACK daisy-chain driver.

If you do not intend to use the MVME162 as system controller, it can occupy any unused double-height card slot.

4.Slide the MVME162 into the selected card slot. Be sure the module is seated properly in the P1 and P2 connectors on the backplane. Do not damage or bend connector pins.

5.Secure the MVME162 in the chassis with the screws provided, making good contact with the transverse mounting rails to minimize RF emissions.

6.Install the MVME712 series transition module in the front or the rear of the VME chassis. (To install an MVME712M, which has a double-wide front panel, you may need to shift other modules in the chassis.)

7.On the chassis backplane, remove the INTERRUPT ACKNOWLEDGE (IACK) and BUS GRANT (BG) jumpers from the header for the card slot occupied by the MVME162.