Disk/Tape Controller Modules Supported
The following VMEbus disk/tape controller modules are supported by the 162Bug. The default address for each controller type is First Address and the controller can be addressed by First CLUN during commands BH, BO, or IOP, or during TRAP #15 calls .DSKRD or .DSKWR. Note that if another controller of the same type is used, the second one must have its address changed by its onboard jumpers and/or switches, so that it matches Second Address and can be called up by Second CLUN.
| First | First | Second | Second |
Controller Type | CLUN | Address | CLUN | Address |
|
|
|
|
|
|
|
|
|
|
CISC Embedded Controller | $00 (NOTE 1) | |||
|
|
|
|
|
MVME320 - Winchester/Floppy Controller | $11 (NOTE 2) | $FFFFB000 | $12 (NOTE 2) | $FFFFAC00 |
|
|
|
|
|
MVME323 - ESDI Winchester Controller | $08 | $FFFFA000 | $09 | $FFFFA200 |
|
|
|
|
|
MVME327A - SCSI Controller | $02 | $FFFFA600 | $03 | $FFFFA700 |
|
|
|
|
|
MVME328 - SCSI Controller | $06 | $FFFF9000 | $07 | $FFFF9800 |
|
|
|
|
|
MVME328 - SCSI Controller | $16 | $FFFF4800 | $17 | $FFFF5800 |
|
|
|
|
|
MVME328 - SCSI Controller | $18 | $FFFF7000 | $19 | $FFFF7800 |
|
|
|
|
|
MVME350 - Streaming Tape Controller | $04 | $FFFF5000 | $05 | $FFFF5100 |
|
|
|
|
|
NOTES: (1) If an MVME162 with a SCSI port is used, then the MVME162 module has CLUN 0.
(2)For MVME162s, the first MVME320 has CLUN $11, and the second MVME320 has CLUN $12.