Debugger General Information
Manufacturing Test Process
During the manufacturing process for MVME162 modules, the manufacturing test parameters and testing state flags are stored in NVRAM. These strings are
3installed during the manufacturing process and result in the product performing manufacturing tests. None of these tests harm the product or system into which a module is installed. Entering an ASCII break on the console port from a terminal terminates these tests.
The two state flags that start the test processes are:
FLASH EMPTY$00122984
and
Burnin test$00000000
If either string is in the first location of NVRAM ($FFFC0000), the test process starts.
This note is to inform users about the manufacturing test process; it is not intended to instruct customers in its use. Motorola reserves the right to delete, change, or modify this process.
MVME162 Embedded Controller Installation Guide |