Zanussi ZCE 531 GB manual Electrical Connections

Models: ZCE 531 GB

1 24
Download 24 pages 10.86 Kb
Page 7
Image 7
ELECTRICAL CONNECTIONS

ELECTRICAL CONNECTIONS

Manual backgroundAny electrical work required to install this hob and the supply cable should be carried out by a qualified electrician or competent person, in accordance with the current regulations.

Manual backgroundTHIS COOKER MUST BE EARTHED.

Manual backgroundThe manufacturer declines any liability should these safety measures not be observed.

Manual backgroundBefore any maintenance or cleaning can be carried out, you must DISCONNECT the cooker from the electricity supply.

This cooker is designed to be connected to a 230-240V AC, 50Hz electrical supply.

To connect to the electricity supply, use cable type H05 RR-F.

Before connection, make sure the electricity supply voltage is the same as that indicated on the rating plate.

The cooker is supplied without supply cable. A flexible supply cable must be fitted, in accordance with the specification gived in the relevant table no. 1.

The electrical connection should be made using a double pole isolating switch (cooker control switch) with at least 3mm contact separation in all poles. The cable must have conductors of sufficiently high cross-sectional area to prevent overheating or deterioration.

The switch should be sited within 2m of the cooker and be easily accessible at all times.

The yellow-green grounding cable must not be interrupted by the switch.

NOTE: The earth wire should be about 2 cm longer than the live and neutral wires.

After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 50°C above the ambient temperature.

The manufacturer declines any responsibility should these safety instructions not be carried out.

Manual background If the supply cable is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.

Before connecting check that:

The fuse and household electrical installation can carry the absorbed current of the appliance (see rating plate);

The cooker connection outlet or the cooker control switch is easily accessible when the appliance is installed.

How to proceed?

Unscrew and remove the protective cover at the back of the appliance;

Connect the power cable to the terminal block of the cooker according to the table no.1;

Secure by means of cable clamp;

Make sure that the connection to the terminal block is matching the supply system, see table no.1;

Refit and screw the protective cover on the back of the appliance.

 

 

 

 

 

 

 

 

 

Table no. 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated voltage

 

 

 

230 V 1N

 

Connection type

Single phase (UK)

 

Cable connection

 

1

2

3

4

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to the terminal block

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L1

 

 

 

 

N

 

PE

 

 

 

 

 

 

 

 

Mains Voltage

 

 

 

 

 

230 V

 

 

 

 

 

 

 

 

 

 

Voltage of heating elements

 

 

 

 

 

230 V

 

 

 

 

 

 

 

 

 

 

Fuse capacity

 

 

 

 

 

32 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cable section

 

 

 

3 x 6 mm2

 

7

Page 7
Image 7
Zanussi ZCE 531 GB manual Electrical Connections