| 300 mm. |
|
|
WALL FACE |
|
|
| |
|
|
|
| BACK OF COOKER |
580 mm. | mm. |
|
| ENGAGEMENT EDGE FOR |
LEVELLING FEET |
| STABILITY BRACKET | ||
| 100 |
| ||
|
|
|
| |
|
|
| A | BASE OF COOKER |
|
|
|
| |
| PENCIL LINE ON THE FLOOR |
|
|
|
|
| 295 mm. |
|
|
| PLAN VIEW OF THE COOKER |
| SIDE VIEW | |
FO 0179 |
| OF THE COOKER | ||
|
|
|
|
Fig. 2
Fitting the Stability Bracket (Not supplied)
If the cooker has to be installed with a flexible supply pipe, it is necessary that a stability device is fitted. (See "Important Safety Requirements").
The stability bracket is to be fitted by the installer and these instructions should be read in conjunction with the leaflet packed with the stability bracket.
Place the cooker in its intended position and level cooker.
Mark off 295mm (11 1/2") from the right hand side of the cooker as shown, this is the centre line of the bracket fixing.
Draw a line 100mm (4") from the front edge of the levelling feet (see Fig. 2) and remove cooker from its position. Mark off 480mm (19") back from this line on the centre line of the bracket to locate the front edge of the lower bracket.
Fix lower bracket (with two fixing holes) to the floor, then measure height from floor level to engagement edge on back of cooker, dimension 'A' of Fig. 2.
Assemble upper bracket to lower bracket so that underside of bracket is dimension 'A' +3mm (1/8") above floor level.
Should the stability bracket currently installed not allow the cooker to stand correctly, ask the installer to replace it with the correct type.
Connecting to Gas
This cooker is designed to be installed with an appliance flexible connection. Connection is made to the RC 1/2 (1/2" B.S.P.) threaded entry pipe located just below the hotplate level on the rear
The gas bayonet connector must be fitted in the shaded area indicated in the diagram. Take into account that it must be possible to pull the cooker forward sufficiently. The hose must not get caught on the stability bracket.
Note:
For certain types of gas bayonet connection used, it may not be possible for the appliance to be pushed fully back to the wall stops.
Important:
Flexible tubing MUST comply with BS.669 Current Edition.
600 |
|
| 450 |
| 130 |
FO 0180 | Fig. 3 |
16