CONVERSION OF GAS

Your cooker is designed to work with natural gas, and is convertible for use witth propane or butane.

The LPG conversion kit is available from your

Service Force Centre and must be fitted by a

Corgi Registered engineer.

For changing the gas type it is necessary to:

replace the nozzles (hob);

adjust the minimum level (hob);

check the gas connection;

Fix the label supplied with the appliance (in the nozzles bag) corresponding to the gas type utilised.

SPECIFICATION NOZZLES

Table no.1

(Cat : II 2H3+)

Burner

Normal

Simmer

By-

Gas Type

Pressure

Nozzle

Cons

power

power

pass

diameter

 

 

(mbar)

3

g/h

 

(kW)

(kW)

(mm)

 

(mm)

 

 

 

m /h

 

 

 

 

Natural Gas

20

1.19

0,267

-

RAPID

3,00

0,72

0,42

Butane

28-30

0,88

-

218,1

 

 

 

 

Propane

37

0,88

-

214,2

SEMI-

 

 

 

Natural Gas

20

0.96

0,190

-

2,00

0,43

0,32

Butane

28-30

0,71

-

145,4

RAPID

 

 

 

Propane

37

0,71

-

142,8

 

 

 

 

 

 

 

 

Natural Gas

20

0.70

0,095

-

AUXILIARY

1,00

0,35

0,29

Butane

28-30

0,50

-

72,7

 

 

 

 

Propane

37

0,50

-

71,4