INSTALLATION

This cooker must be installed in accordance with the IEE Wiring Regulations (Current Edition). Detailed recommendations are contained in the following British Standards Codes Of Practice:

B.S. 6172/ B.S. 5440, Par.2 and B.S. 6891 Current Editions.

The appliance must be installed in accordance with " X " specification (EN60.335-2.6). The cooker must not be installed higher than the worktop.

Please ensure that when the appliance is installed it is easily accessible for the engineer in the event of a breakdown.

Before your appliance is connected to the mains electricity supply, check to ensure that the voltage and the frequency shown on the rating plate corresponds with your supply voltage.

This appliance must be earthed.

The manufacturer declines any responsibility for possible damages resulting from an installation which doesn't comply with current legislation.

-Installation of flues and ventilation for gas appliances of rated input not exceeding 60 kW (1st, 2nd and 3rd family gases) – Part 2 Specification for installation of ventilation for gas appliances – BS 5440;

-Gas burning appliances – Part 3 Domestic cooking appliances burning gas – BS 5386;

-Specification for installation of low pressure gas pipe work of up to 20mm (R1) in domestic premises (2nd family gas)

– BS 6891;

-Pipe threads for tubes and fittings where pressure-tight joints are made on the threads (metric dimensions) – BS 21: 1985;

-Flexible hoses, end fittings and sockets for gas burning appliances – BS 669;

Installation of domestic gas cooking appliances (1st, 2nd and 3rd family gases) – BS 6172: 1990;

LOCATION

Remove all the packaging and install the cooker in a dry, ventilated room not near curtains, paper, alcohol, petrol etc (See figure).

The appliance must be set on a heatproof floor. The adjustable feet must not be removed.

L.P.G. cookers or ovens MUST NOT be installed below ground level, i.e. in a basement, or aboard any boat, yacht or other

690 mm

20mm

600 mm

20mm

690 mm

150 mm

20mm

20mm

vessel.

This appliance is approved to class “1” regarding overheating of surrounding surfaces.

It is mandatory to keep 20mm distance to the adjacent furniture.

The cooking appliance must be fitted with a stability chain firmly secured to the wall (see fig).

Ventilation

The room containing the cooker should have an air supply in accordance with B.S. 5440: Part 2: Current Editions.

The following requirements for ventilation must be met.

Stability hook

Firmly fix chain to rear

of cooker

Stability chain

Chain to be as short

as possible.

6

Page 6
Image 6
Zanussi ZCM 531 GB manual Installation, Location, Ventilation, Vessel