Superior GHC/GRD-5500 Gas Conversion Kits, Cold Climate Insulation, Installation Accessories

Models: GHC/GRD-5500

1 20
Download 20 pages 60.51 Kb
Page 16
Image 16
COLD CLIMATE INSULATION

COLD CLIMATE INSULATION

If you live in a cold climate, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level.Ensure that the clearance require- ments for venting are always maintained.

To avoid air intrusion, surround material must be caulked where it meets the black metal facing of the appliance. Only use a noncom- bustible caulking material to seal this area.

Do not place insulation materials within the 1" gas vent system clearance space.

INSTALLATION ACCESSORIES

The following accessory items are available for use in the installation of this appliance.

Outside Air Kits Models FOAK and FOAK-LD

Outside Air kits are available with duct (FOAK-

4)and without duct (FOAK-4LD) for use if outside combustion air is required or desired. If model FOAK-4LD is used it must be used in conjunction with locally purchased, non-com- bustible Class 1 or Class 0 flexible duct.

GAS CONVERSION KITS

WARNING: THIS CONVERSION KIT SHALL BE INSTALLED BY A QUALIFIED SERVICE AGENCY IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND ALL APPLI- CABLE CODES AND REQUIREMENTS OF THE AUTHORIZED AGENCY HAVING JURISDICTION. IF THE INFORMATION IN THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE, EXPLOSION OR PRODUCTION OF CARBON MONOX- IDE MAY RESULT CAUSING PROPERTY DAMAGE, PER- SONAL INJURY OR LOSS OF LIFE. THE INSTALLATION IS NOT PROPER AND COMPLETE UNTIL THE OPERATION OF THECONVERTEDAPPLIANCEISCHECKEDASSPECIFIEDIN THE OWNER INSTRUCTIONS SUPPLIED WITH THE KIT.

AVERTISSEMENT: CET ÉQUIPEMENT DE CONVERSION SERA INSTALLÉ PAR UNE AGENCE QUALIFIÉE DE SER- VICE CONFORMÉMENT AUX INSTRUCTIONS DU FABRICANT ET TOUTES EXIGENCES ET CODES APPLICABLES DE L'AUTORISÉS AVOIR LA JURIDICTION. SI L'INFORMATION DANS CETTE INSTRUCTION N'EST PAS SUIVIE EXACTEMENT, UN FEU, EXPLOSION OU PRO- DUCTION DE PROTOXYDE DE CARBONE PEUT RÉSULTER LE DOMMAGES CAUSER DE PROPRIÉTÉ, PERTE OU BLESSURE PERSONNELLE DE VIE. L'AGENCE QUALIFIÉE DE SERVICE EST ESPONSABLE DE L'INSTALLATION PROPRE DE CET ÉQUIPMENT. L'INSTALLATION N'EST PAS PROPRE ET COMPLÉTE JUSQU'À L'OPÉRATION DE L'APPAREIL CONVERTI EST CHÉQUE SUIVANT LES CRITÈRES ÉTABLIS DANS LES INSTRUCTIONS DE PROPRIÉTAIRE PROVISIONNÉES AVEC L'ÉQUIPEMENT.

Outside Combustion Air Kits

 

 

(with duct)

81L87

FOAK-4

(without duct)

81L88

FOAK-4LD

 

 

 

In Canada

THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN1-B149.1

AND .2 INSTALLATION CODE.

LA CONVERSION DEVRA ÊTRE EFFECTUÉE CONFORMÉMENT AUX RECOMMANDATIONS DES AUTORITÉS PROVINCIALES AYANT JURIDICTION ET CONFORMÉMENT AUX EXIGENCES DU CODE D'INSTALLATION CAN1- B149.1 ET.2.

Gas conversion kits are available to adapt your appliance from the use of one type of gas to the use of another. These kits contain all the neces- sary components needed to complete the task including labeling that must be affixed to en- sure safe operation.

Kit part numbers are listed on the next page and the following steps detail the conversion procedure.

Note: These kits contain a main orifice which can be used for installation at elevations of 0-2000 Ft. (610 m.) For elevations greater than that, use the correct orifice as shown in table 2 on page 2.

Step 1. Turn off the gas supply to the appliance. Open the doors or remove the enclosure panel.

Step 2. Carefully remove the two (5500 Mod- els) or four (6500 Models) smaller logs on top. Then remove the two (2) main logs. Exercise care as not to break the logs.