Zanussi ZCM 640 ZCM 641 Instructions for the Installer, Important Safety Requirements, Dimensions

Models: ZCM 640 ZCM 641

1 20
Download 20 pages 19.63 Kb
Page 15
Image 15

Instructions for the Installer

Technical Data

 

Hob

 

 

 

 

 

 

 

 

Appliance Class 2 sub class 1 and Class 1

 

Rear left burner (semi-rapid)

 

 

2.0 kW

APPLIANCE CATEGORY:

II2H3+

Front left burner (rapid)

 

 

3.0 kW

APPLIANCE GAS SUPPLY: Natural Gas 20 mbar

Rear right burner (semi-rapid)

2.0 kW

Dimensions

 

 

Front right burner (auxiliary)

 

 

1.0 kW

 

 

Oven

 

 

 

 

 

 

Height

 

 

900 mm

 

 

 

 

2000 W

Depth

 

 

600 mm

Convection Heating Element

 

 

Grill Element

 

 

 

 

1650 W

Width

 

 

600 mm

 

 

 

 

 

 

Convection Fan

 

 

 

 

30 W

Oven Capacity

56 litres / 1.97 Cu. ft

 

 

 

 

Oven light

 

 

 

 

25 W

 

 

 

 

 

 

 

 

 

 

 

 

Cooker rating (total)

 

 

2055 W

 

 

 

 

Supply voltage (50 Hz)

 

 

230 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BURNER

RAPID

 

SEMI-RAPID

 

AUXILIARY

 

TYPE OF

CHARACTERISTICS

 

(large)

 

(medium)

 

(small)

 

 

GAS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POSITION

MAX

MIN

 

MAX

 

MIN

 

MAX

 

MIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOMINALTHERMAL

 

 

 

 

 

 

 

 

 

 

 

NATURAL

VALUE =

POWER kW

3.0

0.65

 

2.0

 

0.45

 

1.0

 

0.33

 

 

 

 

 

 

 

 

 

 

 

 

 

GAS

Hs 37.78 MJ/m3

NOMINAL FLOW

 

 

 

 

 

 

 

 

 

 

 

20 mbar

Ws 50.72 MJ/ m3

0.286

0.062

 

0.190

 

0.043

 

0.095

 

0.031

 

 

 

RATE m3/h

 

 

 

 

 

 

 

NOZZLEREFERENCE

119

Adjust.

 

96

 

Adjust.

 

70

 

Adjust.

 

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

NOMINALTHERMAL

 

 

 

 

 

 

 

 

 

 

 

 

 

POWERkW

2.8

0.65

 

2.0

 

0.45

 

1.0

 

0.33

 

LPG GAS

VALUE =

NOMINAL FLOW

 

 

 

 

 

 

 

 

 

 

 

28-30/37

Hs 49.92 MJ/Kg

RATE g/h

202

47

 

144

 

32

 

72

 

24

 

mbar

Ws 82.09 MJ/ m3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOZZLEREFERENCE

86

40

 

71

 

32

 

50

 

28

 

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Important Safety Requirements

This appliance must be installed in accordance with the Gas Safety (Installation and Use) Regulations (current addition) and the I.E.E. Wiring Regulations.

Detailed recommendations are contained in the following British Standard Codes of Practice - B.S. 6172, B.S. 5440: Part 2 and B.S. 6891: Current Editions.

For appliances installed in the Republic of Ireland please refer to NSAI- Domestic Gas Installation I.S. 813 Current Editions and the ETCI Rules for Electrical Installations.

Provision for Ventilation

The room containing the cooker should have an air supply in accordance with B.S. 5440: Part 2: Current Editions.

The following requirements for ventilation must be met. The cooker should not be installed in a bed sitting room

with a volume of less than 20m3, if it is installed in a room of volume less 5m3 an air vent of effective area of 110cm2 is required; if it is installed in a room of volume between 5m3 and 10m3, an air vent of effective area 50cm2 is required, while if the volume exceeds 11m3 no air vent is required. However, if the room has a door which opens directly to the outside, no air vent is required even when the volume is between 5m3 and 11m3.

If there are other fuel burning appliances in the same room, B.S. 5440: Part. 2: Current Editions should be consulted to determine the requisite air vent requirements.

For appliances installed in the Republic of Ireland please refer to the NSAI- Domestic Gas Installation I.S. 813 Current Editions Table Four.

15