Installing the cabinet

To obtain the best performance from the cabinet, ensure :

·the cabinet is placed in a dry, cool place and is not exposed to direct sunlight.

·the cabinet is not placed close to a source of heat, e.g. a cooker or dishwasher.

·the room in which the cabinet is placed has a temperature of +10C to +32C.

·the cabinet is level.The cabinet should not lean against any wall. If necessary adjust the

feet using the supplied adjustment spanner.

·there is good air circulation around the cabinet and that the air channels below and behind the cabinet are not blocked. The ventilation space above the cabinet and any

grocery/top cabinet must be at least 200 cm². The ventilation space can either be

a)directly above the cabinet, or

b)behind and above the top cabinet. In this case, the space behind the cabinet must be at least

50 mm deep.

If the cabinet is placed in a corner and the side with the hinges faces the wall, the distance between the wall and the cabinet must be at least 10 mm to allow the door to open enough so that the shelves can be removed.

Electrical connection

Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person. This appliance must be earthed.

The manufacturer declines any liability should these safety measures not be observed.

Electrical Requirements

Before switching on, make sure the electricity supply voltage is the same as that indicated on the appliance rating plate.

The appliance is supplied with a 13amp plug fitted. In the event of having to change the fuse in the plug supplied, a 13amp ASTA approved (BS1362) fuse must be used.

Should the plug need to be replaced for any reason. The wires in the mains lead are coloured in accoordance with the following code:

Green and yellow

-Earth

Blue

-Neutral

Brown

-Live

The wire coloured green and yellow must be connected to the terminal marked with the letter "E"

or by the earth symbol or coloured greeen and

a)

b)

50mm

yellow.

The wire coloured blue must be connected to the terminal marked "N" or coloured black

The wire coloured brown must be connected to the terminal marked "L" or coloured red.

Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath.

Zanussi 818 14 54-03/7

15

Page 15
Image 15
Zanussi ZCR135R manual Installing the cabinet, Electrical connection